Troubleshooting - Motor Controller
3A9034B
23
Troubleshooting - Motor Controller
Diagnostics
Diagnostics information can be obtained by observing
the fault codes issued by the Status LEDs. See Table 1
for a summary of LED display formats.
The pair of LEDs built into the controller (one red, one
yellow) produce flash codes displaying all the currently
set faults in a repeating cycle. Each code consists of
two digits. The red LED flashes once to indicate that the
first digit of the code will follow: the yellow LED then
flashes the appropriate number of times for the first
digit. The red LED flashed twice to indicate that the
second digit of the code will follow; the yellow LED
flashes the appropriate number of times for the second
digit.
Example:
B+ Under voltage Cutback (code 23) and Stall Detected
(code 73).
The controller’s two LEDs will display this repeating
pattern:
The numerical codes used by the yellow LED are listed
, page 24, which also lists possible fault
causes and describes the conditions that set and clear
each fault.
NOTE: If there are more than one errors active at one
time, the control will cycle through them and repeat.
Summary of LED Display Formats
The two LEDs have four different display modes,
indicating the type of information they are providing.
Table 1
Code
Display
23
One red, two yellow, two red, three yellow
73
One red, seven yellow, two red, three yellow
Display
Status
Neither LED
illuminated
Controller is not powered on, or
Vehicle has dead battery, or
Severe damage
Yellow LED
flashing
Controller is operating normally
Yellow and red
LEDs both on solid
Controller is in Flash program mode
Red LED on solid
Internal hardware fault detected by the
Supervisor or Primary microprocessor.
Missing or corrupt software. Interrupting
a software download may cause corrup
-
tion of the software. Cycle Power Switch
to clear. Reload software or replace
controller if necessary.
Red LED and
yellow LED flashing
alternately
Controller has detected a fault. 2-digit
code flashed by yellow LED identifies
the specific fault; one or two flashes by
red LED indicate whether first or second
code digit will follow.
Содержание LineDriver 25U670
Страница 15: ...Maintenance 3A9034B 15 Throttle Linkage Adjustment ...
Страница 28: ...Parts Drawing 28 3A9034B Parts Drawing Torque cable cap screws or nuts to 7 8 ft lbs 9 11 N m 1 ...
Страница 31: ...Parts Drawing 3A9034B 31 Parts Drawing Clamped parts must move freely after tightening 1 1 1 1 ...
Страница 34: ...Wiring Diagram Harness 25N661 34 3A9034B Wiring Diagram Harness 25N661 ...
Страница 35: ...Wiring Diagram 3A9034B 35 Wiring Diagram ...
Страница 36: ...Wiring Diagram Harness 25E406 36 3A9034B Wiring Diagram Harness 25E406 ...