Troubleshooting
Troubleshooting
Problem
Cause
Solution
Plugged manifold filter
Replace manifold filter. See
Clogged hose
Clean or replace hose.
Failed solenoid valve
Check for correct operation. Clean
or replace.
No signal to solenoid valve
Check solenoid valve for correct
operation.
Incorrect solenoid valve wiring
Check solenoid valve wiring.
Incorrect signal to solenoid valve
Check if 24 VDC or 120 VAC.
Solenoid muffler plugged
Check and replace mufflers.
No fluid pressure
Check adhesive delivery system.
Heater failure (cold gun)
Check and replace
heater cartridges. See
Replace Heater Cartridge, page 18
No air to solenoid valve
Check air supply.
Dirty or faulty triggering device
Check, clean, or replace triggering
device.
Solenoid valve connected
incorrectly
Check solenoid valve air connections.
No adhesive or incorrect
amount of adhesive out of all
modules when triggered
Clogged manifold passage
Clean or replace manifold.
Plugged nozzle
Clean or replace nozzle.
Failed module in closed position
Check for correct operation.
Clean or replace. See
Plugged module filter
Replace module. See
No adhesive or incorrect
amount of adhesive out of
one/some modules when
triggered
Clogged manifold passage
Clean or replace manifold.
Failed module in open position
Clean or replace module. See
Adhesive out of one/some
modules when not triggered
Adhesive pressure too high
Check and reduce fluid pressure.
3A2805B
13