Installation
Connect Triggering Device
Identify if your model uses a 24 VDC or 110 VAC
solenoid valve. Connect solenoid valve to 24 VDC
or 110 VAC signal.
Improper electrical connection can result in electric
shock. All electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.
1. Loosen the mounting screw and disconnect the
electrical connector (N) from the solenoid valve
(J). Set the gasket and screw aside.
J
N
P
Figure 6 Solenoid Valve Electrical Connector
2. Insert a small screwdriver where the mounting
screw was removed and gently press the
electrical connector (P) out of the electrical
connector housing (N).
3. Thread a three-conductor cable through the strain
relief. Connect the positive and negative wires to
terminals 1 and 2 on the electrical connector (P).
Connect the ground wire to the ground terminal.
2
1
G
N
D
Solenoid Valve Connector
Figure 7
4. Reassemble the electrical connector (P) and
housing (N). Retighten strain relief.
5. Place the gasket on the housing and connect the
electrical connector into the solenoid valve (J)
with the mounting screw. See
Prime Before Using Equipment
The equipment was tested with lightweight oil, which
is left in the fluid passages to protect parts. To avoid
contaminating your fluid with oil, prime the equipment
with hot melt until all of the oil is pushed out before
using the equipment. See
Flush
1. Disconnect or turn off the device which triggers
the solenoid valve.
2. Heat the system to working temperature.
3. Place waste container under the gun to catch the
adhesive.
4. Ensure the nozzle is removed.
5. Press the manual override switch (S) to manually
trigger the solenoid valve.
6. Dispense hot melt (adhesive) until it is clean.
Figure 8
10
3A2805B