DataTrak Operation
10
313840N
Table 1: Diagnostic Codes
Symbol
Code Code
Name
Diagnosis
Cause
Runaway
Pump running faster than
set runaway limit.
Increased air pressure.
Increased fluid output.
Exhausted fluid supply.
E-3
Low Battery
Battery voltage too low to
stop runaway.
Low battery. Replace battery;
see page 11.
E--4
Service
Component 1
Problem with stopping
runaway.
Damaged solenoid.
Damaged valve carriage.
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.
E-4
Disconnected
Solenoid
Solenoid is disconnected.
Solenoid unplugged.
Damaged solenoid wires.
E-6
Blown Fuse
Fuse is blown. Replace
fuse; see page 11.
Faulty solenoid or solenoid
wiring.
Extreme temperatures (above
140°F [60°C]).
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.