DataTrak Operation
313840N
11
Replace DataTrak Battery or Fuse
Replace Battery
1.
Unscrew cable from the reed switch assembly. See
Fig. 2.
2.
Remove DataTrak module from bracket. See Fig. 3.
Take module to a non-hazardous location.
3.
Remove two screws on back of module to access
battery.
4.
Disconnect the used battery and replace with an
approved battery. See Fig. 4.
To reduce the risk of fire and explosion, the battery
and fuse must be replaced in a non-hazardous loca-
tion.
Use only an approved replacement battery, shown in
Table 2, and an approved fuse, shown in Table 3. Use
of an unapproved battery or fuse will void Graco’s war-
ranty and Intertek and Ex approvals.
Fig. 2. Disconnect DataTrak
Fig. 3. Remove DataTrak
ti14053a
Table 2. Approved Batteries
Energizer alkaline # 522
Varta alkaline # 4922
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Содержание DataTrak kit
Страница 13: ...DataTrak Operation 313840N 13 ...