DataTrak Operation
313840N
9
Calibration Procedure
1.
Press and hold
for 5 seconds until Setup menu
appears.
2.
Press
once. Change flow rate units to
cycles/min.
3.
Return to Run Screen. Press and hold
for three
seconds to reset batch totalizer.
4.
Dispense fluid from pump into a graduated con-
tainer.
5.
Convert the actual volume dispensed to cubic centi-
meters (cc). See conversion chart.
6.
Divide the actual volume dispensed (cc) by the
number of cycles indicated on the DataTrak batch
totalizer display.
7.
Press
to enter the Setup screen. Enter the
number from Step 6 in field 2 of the Setup screen.
Units Measured
Multiply by
To get
Gallons (U.S.)
3785
cc
Gallons (Imp)
4546
cc
Liters
1000
cc
Quarts
946
cc
Ounces (U.S.)
29.57
cc
Ounces (Imp)
28.41
cc
Cubic inches
16.39
cc
Cubic feet
28,317
cc
Pints
473
cc
cc
1
cc