Warnings 

6

3A6319E

WARNING

EQUIPMENT MISUSE HAZARD

 

Misuse can cause death or serious injury.

• Do not operate the unit when fatigued or under the influence of drugs or alcohol.

• Do not exceed the maximum working pressure or temperature rating of the lowest rated system 

component. See 

Technical Specifications

 in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See 

Technical 

Specifications

 in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For 

complete information about your material, request Safety Data Sheets (SDSs) from distributor or 

retailer.

• Turn off all equipment and follow the 

Pressure Relief Procedure 

when equipment is not in use.

• Check equipment daily. Repair or replace worn or damaged parts immediately with genuine 

manufacturer’s replacement parts only.

• Do not alter or modify equipment. Alterations or modifications may void agency approvals and 

create safety hazards.

• Make sure all equipment is rated and approved for the environment in which you are using it.

• Use equipment only for its intended purpose. Call your distributor for information.

• Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

• Do not kink or over bend hoses or use hoses to pull equipment.

• Keep children and animals away from work area.

• Comply with all applicable safety regulations.

PLASTIC PARTS CLEANING SOLVENT HAZARD

Many cleaning solvents can degrade plastic parts and cause them to fail, which could cause serious 

injury or property damage.

 

• Use only compatible solvents to clean plastic structural or pressure-containing parts.

• See 

Technical Specifications

 in all equipment manuals for materials of construction. Consult the 

solvent manufacturer for information and recommendations about compatibility.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

• Keep clear of moving parts.

• Do not operate equipment with protective guards or covers removed.

• Equipment can start without warning. Before checking, moving, or servicing equipment, follow the 

Pressure Relief Procedure

 and disconnect all power sources.

PERSONAL PROTECTIVE EQUIPMENT 

Wear appropriate protective equipment when in the work area to help prevent serious injury, including 

eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not 

limited to:

• Protective eyewear, and hearing protection. 

• Respirators, protective clothing, and gloves as recommended by the fluid and solvent 

manufacturer.

Содержание 96G500

Страница 1: ...or Professional Use Only Not approved for use in explosive atmospheres or hazardous classified locations Models see page 3 5100 psi 35 1 MPa 351 6 bar Maximum Pump Output Pressure Important Safety Ins...

Страница 2: ...10 Wiring and Installation Diagrams 11 Setup 12 Pressure Relief Procedure 12 Connecting to Auxiliary Fittings 12 Pressure Relief Valves 12 Setting Pump Outlet Volume 13 Load Pump with Grease 13 Prime...

Страница 3: ...3 Pump To help with understanding each component that makes up the Model Number see Under standing the Model Number page 4 The tables below shows the relationship between each Part Number and its rela...

Страница 4: ...s being a G3 G Grease G3 A Identifies pump as being a G3 A Oil Code aa Power Source 24 24 Volts DC Code bb Operation Control NC No Controller Code cc Reservoir Capacity Liters 8L 8 Liters 12 12 Liters...

Страница 5: ...d components will pierce skin This may look like just a cut but it is a serious injury that can result in amputation Get immediate surgical treatment Do not point dispensing device at anyone or at any...

Страница 6: ...traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety r...

Страница 7: ...f Valves page 20 D Zerk Inlet Fill Fitting 1 included grease models only E Pump Outlet Plug 2 included F Volume Control Spacers 2 included More spacers less output volume per stroke also see FIG 9 pag...

Страница 8: ...Progressive Divider Valve Key A Connected to fused power source B Pressure Relief Valve not included required for each outlet user supplied C Supply Hose user supplied D Series Progressive Divider Va...

Страница 9: ...ed power source B Pressure Relief Valve not included required for each outlet user supplied C Supply Hose user supplied D Injectors E To lube points F Pressure Switch G Vent Valve not included availab...

Страница 10: ...ed spacers if there is still a gap after adjusting the bracket System Wiring Fuses Fuse Kits are available from Graco The table identifies the correct fuse to use for the input voltage and the cor res...

Страница 11: ...e pump Power DIN DC 15 foot Pin and Related Wire Color FIG 6 Low Level Outputs See Low Level Output Option page 15 for functional description See Dimensions page 21 for ratings Pins FIG 7 Pin Pin Name...

Страница 12: ...and before cleaning checking or servicing the equipment FIG 8 NOTICE Do not attach unsupported equipment to auxiliary fit tings such as fill ports and pump element Attaching unsupported equipment to t...

Страница 13: ...nt and adjust as necessary to ensure desired lubrica tion dispense Load Pump with Grease To ensure optimal performance from the G3 pump Only use NLGI 000 2 greases appropriate for the application auto...

Страница 14: ...filled with lubricant The pump only requires priming the first time it is used or if it is allowed to run dry 1 Loosen pump element fitting FIG 11 NOTE When loosening the pump element fitting do not l...

Страница 15: ...l Output Option The low level signal is monitored across PINS 3 and 4 For PIN 3 and 4 locations and wir ing information see the Low Level Outputs page 11 NOTE A low level warning is triggered when the...

Страница 16: ...rds LCDs liquid crystal displays and other electronic components Recycle according to applicable regulations Do not dispose of electronic components with household or commercial waste Deliver remainin...

Страница 17: ...Reservoir is being pressurized during filling Ensure vent port is not plugged If problem persists contact Graco Customer Service or your local Graco distributor for assistance Unit not pumping during...

Страница 18: ...s 18 3A6319E Parts 43 36 6 44 30 31 16 10 22 40 42 24 5 27 26 25 41 29 1 3 21 20 23 32 4 2 42 45 8 Liter Model Reservoir for 12 Liter and Larger Models 20 21 12 10 See 8 Liter Model for all other part...

Страница 19: ...guide 15L 1 ROD guide 20L 1 21 SPRING B compression 8L 1 SPRING A compression 12L 2 SPRING A compression 15L 2 SPRING B compression 20L 2 22 19B457 SEAL grease 16 mm id 1 23 NUT 1 24 Plate follower 1...

Страница 20: ...on and Repair Kits Part Description Qty 16C807 VALVE pressure relief 500 3500 psi 3 44 MPa 34 4 bar 24 1 MPa 241 bar Set pressure 3000 psi 10 20 68 MPa 206 8 bar 10 Included in Kit 571028 1 563156 VAL...

Страница 21: ...dth Depth Inches cm Inches cm Inches cm 8L 22 34 56 74 8 94 22 70 10 37 26 34 12L 27 34 69 44 8 94 22 70 10 37 26 34 15L 30 99 78 71 8 94 22 70 10 37 26 34 20L 37 09 94 21 8 94 22 70 10 37 26 34 Model...

Страница 22: ...Switch Rating 200 VDC Maximum Switching Current 0 5 A Maximum Carry Current 1 2 A Maximum Fluid Grease NLGI 000 2 Pumps Up to 3 Pump Output 2 spacers per outlet 0 12 in 3 minute 2 cm3 minute 1 spacer...

Страница 23: ...California Proposition 65 3A6319E 23 California Proposition 65 CALIFORNIA RESIDENTS WARNING Cancer and reproductive harm www P65warnings ca gov...

Страница 24: ...t disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN...

Отзывы: