Setup
12
3A6319E
Setup
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
Relieve pressure in system using two (2) wrenches
working in opposite directions on the pump element
and the pump element fitting, to slowly loosen only until
fitting is loose and no more lubricant or air is leaking
from fitting.
NOTE:
When loosening the pump element fitting, do
not loosen the pump element. Loosening the pump ele
-
ment changes the output volume.
Connecting to Auxiliary Fittings
Pressure Relief Valves
NOTE:
A pressure relief valve can be purchased from
Graco.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection, splash
-
ing fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.
F
IG
. 8
NOTICE
Do not attach unsupported equipment to auxiliary fit
-
tings such as fill ports and pump element. Attaching
unsupported equipment to these fitting can result in
irreparable housing damage.
• Always use two (2) wrenches working in opposite
directions when connecting anything to the pump
element or auxiliary fittings. See F
. 8 for an
example.
• Torque the pump element fittings to 50 in-lb
(5.6 N•m).
• When connecting pump element into housing,
torque to 50 in-lb (5.6 N•m).
To prevent over-pressurization, which can result in
equipment rupture and serious injury, a pressure
relief valve appropriate for the lubrication system
must be installed close to every pump outlet to alle
-
viate unintended pressure rises in the system and
protect the G3 pump from damage.
• Only use a pressure relief valve that is rated for
no more than the working pressure of any com
-
ponent installed in the system.
• Install a pressure relief valve close to every
pump outlet; before any auxiliary fitting.