Installation
10
3A6319E
Installation
Unpack
The pump module was carefully packaged for shipment
by Graco. When the package arrives, perform the fol
-
lowing procedure to unpack the units:
1. Inspect the shipping box carefully for shipping
damage. Contact the carrier promptly if damage is
discovered.
2. Unseal the box and inspect the contents carefully.
There should not be any damaged parts.
3. Compare the packing slip against all items included
in the box. Any shortages or other inspection
problems should be reported immediately.
Choose an Installation Location
• Select a location that adequately supports the
weight of the G3 pump and lubricant, as well as all
plumbing and electrical connections.
• Refer to the mounting hole layouts provided in
, page 21. No other
installation configuration should be used.
• Use designated mounting holes and provided con
-
figurations only.
• Use the five (5) fasteners (included) to secure the
G3 pump to the mounting surface. Three (3) fasten
-
ers are used for the bottom bracket and two (2) fas
-
teners are used for the top bracket.
• Adjust top mounting bracket, if necessary, to align
the bracket with the mounting surface (F
. 5).
• Insert (user supplied) spacers if there is still a gap
after adjusting the bracket.
System Wiring
Fuses
Fuse Kits are available from Graco. The table identifies
the correct fuse to use for the input voltage and the cor
-
responding Graco Kit number.
Recommendations for Pump Usage in
Harsh Environments
• If using a DIN style power or alarm harness with a
right angle mating connector, make sure the con
-
nector does not exit the unit in the UP direction.
• Use a corrosion preventative electrical grease on all
contacts.
NOTICE
To prevent equipment damage, observe precautions
for handling electrostatic sensitive devices. Touch
ground before handling pump.
AUTOMATIC SYSTEM ACTIVATION HAZARD
If the system is equipped with an automatic timer
(user supplied) that activates the pump lubrication
system when power is connected, or when exiting
the programming function, unexpected activation of
the system could result in serious injury, including
skin injection and amputation.
Before installation or removal of the lubrication pump
from the system, disconnect and isolate all power
supplies and relieve all pressure.
F
IG
. 5
NOTICE
Fuses (user supplied) are required on all DC mod
-
els. To avoid equipment damage:
• Never operate G3 pump DC models without a
fuse installed.
• A fuse of the correct current rating must be
installed in line with the power entry to the
equipment.
Input Voltage
Fuse Value
Graco Kit No.
24 VDC
4 A
571040