Troubleshooting
3A6319E
17
Troubleshooting
checking or repairing the equipment.
Problem
Cause
Solution
Unit does not power on
Incorrect/loose wiring
Refer to
page 10.
Unit does not power on (DC models
only)
Tripped external fuse due to internal
component failure
Contact Graco Customer Service.
Tripped external fuse due to pump
-
ing non-cold weather lubricant in
cold weather -13°F (-25°C)
Replace lubricant with pumpable
lubricant, rated for environmental
conditions and application.
Replace fuse.
Lubricant leaks past seal located on
the bottom of the reservoir
Reservoir retaining tabs are cracked
or broken
Replace reservoir.
Reservoir is being pressurized during
filling
Ensure vent port is not plugged.
If problem persists, contact Graco
Customer Service or your local
Graco distributor for assistance.
Unit not pumping during ON cycle,
but controller lights and functions
Failed motor
Replace unit.
Follower plate is not going down
Air is trapped in the reservoir
between the follower plate and lubri
-
cant
instructions, page 13.
Ensure air is purged.
Pump takes several minutes before it
begins pumping at the highest pump
volume setting (no stroke adjust
spacers installed)
Pumping non-cold weather lubricant
in cold weather -13°F (-25°C)
Add 1 stroke adjust spacer and
adjust lube cycle time to accommo
-
date the difference in pump volume
per stroke.
After wiring and installing equipment
pump is not working
Pump wired backwards
Rewire pump. See
, page 11.