Repair
48
333586E
Repair
Disconnect Pump from Platen
The Pump is mounted to the Platens by different mount-
ing kits. See the Repair Kits on page 80.
55 Gallon Platen
1. Follow the
2. Turn off power to the ram:
a. If using an ambient Single Ram Supply System,
turn the red Disconnect Switch (AZ) OFF.
b. If using a heated Single Ram Supply System,
turn the red Disconnect Switch (AZ) OFF.
c. If using an ambient Tandem Ram Supply
System, turn the red Disconnect Switch (AZ)
OFF on the Ram Supply Unit that requires repair
only.
d. If using a heated Tandem Ram Supply System,
turn the red Disconnect Switch (AZ) OFF on the
Ram Supply Unit that requires repair only.
3. Remove four hex screws (426), four clamps (427),
and washers (425).
4. Carefully pull Pump away to prevent damage to
Pump inlet and remove o-ring (428).
F
IG
. 43: 55 Gallon Mounting Kit
TI10422A
426
425
427
428
Heated Platen
Ambient Platen
428
426
427