Troubleshooting
18
3A8307D
Alarms
Meter does not shut off at the preset
value
Preset limit incorrectly set
Set AddL (Additional Dispense Limit)
to a lower value to prevent mishaps.
Valve seat (30) is worn
Replace the valve seat (30).
Trigger is manually held open when
the solenoid activates
Latch the trigger during present dis
-
penses.
Weak batteries
Replace old batteries with four (4)
new batteries - E91 alkaline Ener
-
gizer recommended.
Trigger assembly is damaged
Replace the trigger assembly
(18F172).
Dynamic inlet pressure is exceeded Reduce the flow rate, fluid viscosity
is causing excessive pressure drop.
Solenoid damaged
Replace the solenoid (18F171).
The temperature limit is exceeded
Limit the operating temperature to
the maximum allowed.
Faulty solenoid wire connection
Check and repair, as needed, the
solenoid wire connection to the ter
-
minal block within the bezel housing.
Leaks from nozzle
Worn nozzle seals
Replace the nozzle (4).
Valve seat (30) is worn
Replace the valve seat (30).
Alarm
Alarm Type
Cause
Solution
PrE
Over-Dispense Alarm Fluid flow does not stop upon
reaching the present amount.
See
, page17.
AddL
Limit-Exceeded Alarm The trigger is manually held open until
the pre-defined limit is exceeded.
Release trigger or adjust the limit to
a larger amount.
Err7
Calibration Error
An out of range of normal invalid
calibration factor is obtained during
calibration operation.
Recalibrate the meter. Make sure
that the correct unit of measure is
selected and that the correct
volumetric calibration container is
being used.
Contact Graco Customer Service if
recalibration is unsuccessful.
bAtt
Low Battery Alarm
The battery voltage is too low to
operate the meter.
Replace batteries.
One of the batteries is installed with
incorrect polarity.
Check for proper polarity for all four
(4) batteries, and correct as
needed.
Problem
Cause
Solution