Operation
14
3A8307D
Battery Installation
NOTE: The reference numbers in the following
instructions refer to and F
, page 7.
2. Remove the impact guard (37).
3. Remove the four (4) screws (9) from the meter
housing (10), and remove the electronics bezel (1).
4. Locate the battery pack and remove the batteries
(36).
5. Dispose of the batteries according to local
regulations for battery disposal.
6. Insert new batteries as shown on the battery holder
(negative and positive positions). Press down
firmly.
7. Reinstall the battery pack.
8. Position the wires as shown in F
. 9, to minimize
pinching the wires between the meter housing and
the bezel housing.
9. Inspect the bezel seal (2) for damage. Replace, if
needed.
10. Place the electronics bezel (1) onto the meter
housing (10).
11. Reinstall the four (4) screws (9), tightening the
screws in a diagonal pattern to 15 - 25 in-lb (1.7 -
2.8 N•m).
F
IG
. 8
9
10
36
2
1
37
Содержание 25U085
Страница 12: ...Operation 12 3A8307D Operation Flowchart ...
Страница 15: ...Operation 3A8307D 15 12 Reinstall the impact guard 37 FIG 9 ...
Страница 19: ...Notes 3A8307D 19 Notes ...
Страница 22: ...Parts 22 3A8307D PM8 PM20 Pressure Drop 10 Weight Oil at 70 F 21 C ...