Advanced Setup Screen 4
On the Advanced Setup Screen 4, press ‘F1’ or select
the
button to display the System Main Screen.
Press ‘F2’ or select the
button to return to the
previous screen. Press ‘F4’ or select the
button to
continue to the next screen.
The content and functions of this screen are as follows:
Pressure sensor offset
The operator may input values to adjust the pressure
offset on the sensors.
Pressure limit
If the Part A or B pressure is higher than the preset max
pressure, the system will activate the alarm and send
the alarm signal to customer system.
During dispensing, the system will check the difference
between part A and B. If the pressure difference is
higher than preset limit, the system will send the alarm
signal and stop dispensing.