HMI Display Operation and Identification
28
3A7526B
System Main Screen
On the Automatic Screen 1, press
button to display
the System Main Screen. On this screen, the operator
can switch the system to Automatic mode, Manual
mode, Setup mode, System Relief function or Advanced
Mode.
Press ‘F1’ or select the
button to display language
options (Chinese or English). Press ‘F2’ or select the
button to display the System Information Screen.
If the operator has already set up password protection
on
password must be entered to visit the Setup Screens.
To open the Advanced mode, the operator must enter
the password
1492
.
The Advanced option won’t show
until the password has been entered.
Select ‘System Relief’ button, the system will identify
whether the inlet valve (AL or AM) is closed. If the Inlet
Valve (AL or AM) is opened, it will be closed. Then the
MD2 Dispense Valve (AE) will be opened. The whole
system pressure is relieved. When the ‘System Relief’ is
selected, the real-time pressure of part A and part B will
be displayed on the System Main Screen.
System Information Screen
General system information can be found in this screen.
Press ‘F1” or select the
button to return to the
System Main Screen.
F
IG
. 16 System Main Screen
F
IG
. 17 System Information Screen
Содержание 25R128