HMI Display Operation and Identification
3A7526B
39
Advanced Setup Screen 3
On the Advanced Setup Screen 3, press ‘F1’ or select
the
button to display the System Main Screen.
Press ‘F2’ or select the
button to return to the
previous screen. Press ‘F4’ or select the
button to
continue to the next screen.
The content and functions of this screen are as follows:
Enable remote E-stop
If this function is selected, the PR-X system can be shut
down from an external signal. When the signal changes
to a `0', the PR-X system will shut down. This function
acts the same as the Emergency Stop Switch (BB) on
the front of the PR-X control box.
Enable sequence mode
If this function is selected, the PR-X system will run in
sequence mode. In this mode, the operator can edit the
working sequence (The sequence includes 16 steps
maximum. The operator can edit step 1 to 14, as step 0
and 15 are tied to pre-charge and depressurization).
When the system works in automatic status, the
Customer Control Box (N) can send ‘dispense’ signal to
start the sequence mode and then dispense step by
step.
Enable pressure check after homing
If this function is selected, the system pressure will be
checked when the piston is in the home position.
Enable remote supply lock (For cartridge version
only)
If this function is selected, the supply cartridge can not
feed the material until the customer’s control system
sends out the unlock signal.
F
IG
. 33
Advanced Setup Screen - 3
Содержание 25R128