Repair
30
3A5354B
Repair
Air Motor
Remove Air Motor
1. Turn the main power switch (MP) OFF.
2. Perform the
20 and follow the Pressure Relief Procedure in your
pump manual.
3. Perform the Disconnect Displacement Pump proce-
dure in the Check-Mate Pump Packages, Instruc-
tions-Parts manual.
4. Disconnect the air hose from the air motor (B).
5. Remove Quick Coupler: Remove the clip (GC), and
slide the coupling cover (GB) up to remove the cou-
pling (GA).
6. Disconnect air motor: Remove the screws and
washers securing the motor (B) to the mounting
bracket (J). See F
Install Air Motor
20 liter (5 gallon) platen:
1. Attach the motor (B) to the mounting bracket (J) with
screws and washers. Tighten the screws until they
are flat against the lock washers. See F
. 29.
2. Connect the air hose to the motor (B).
F
IG
. 28: Remove Quick Coupler
GB
GC
GA
ti10508a
F
IG
. 29: Air Motor Disconnection
Washer
Screw
B
J
Содержание 25D117
Страница 19: ...Setup 3A5354B 19 NOTE Users can set up the language temperature unit and weight unit etc before testing...
Страница 42: ...Electrical Schematics 42 3A5354B Pump and Platen Schematic Cable from switch 36 included with heater 19 6 6...
Страница 49: ...Technical Specifications 3A5354B 49...