Setup
18
3A5354B
System Heat Up
NOTE:
Operate at the lowest temperature and pressure
necessary for your application.
1. Turn the main power switch (MP) on the electrical
control panel door to the ON position. See F
2. Press the On/Off key
while in the Heat Run
screen to turn the heaters on for the enabled heat
zones.
3. Press
on the ADM to set up the warm melt
zones. Press
to set up the Zone type. Select
Zone Type and set the temperature. Press
to
complete the setup.
4. Press
or
to activate the zone for warm
melt running. The light will change from yellow to
green. The alarm light will also be lit as the zone is
heating.
5. Press the left horizontal arrow
to go into the
Diagnostic screen. Information on the system heat-
ing can be seen here.
To prevent skin injection and splashing fluid from a
burst hose, never pressurize the system while using
warm melt materials before turning on heat.
Many warm melt materials tend to expand when
heating and may cause a heated hose to burst.
Avoid the potential of bursting a hose by opening
the dispense valve during system heat up and lock-
ing the dispense valve trigger open every time you
shut the system down.
F
IG
. 17: Power Switch ON
I ON
O OFF
MP