Appendix A - ADM
116
333347F
Errors
The Errors screens store a maximum of 200 errors. See
on page 40. The errors list can
be downloaded in the USB logs. See
Diagnostic
This screen shows details of various items to aid in trou-
bleshooting the system. This screen can be hidden by
de-selecting “Enable Diagnostics Screen” on the Sys-
tem 3 screen. The flow rate updates every 15-20 sec-
onds with the average flow rate over the last 15-20
seconds.
The following information is displayed.
CAN:
24 VDC power supply voltage reading (18-28
VDC)
DI:
System Digital Inputs
0: Not Used
1: Not Used
2: Pump Cycle Switch Up
3: Pump Cycle Switch Down
DO:
System Digital Outputs
0: Pump Solenoid
1: Fill Solenoid
2: Light Tower Green Light
3: Light Tower Red Light
ISO DI:
Customer Digital Inputs
0: Customer Input 1
1: Customer Input 2
2: Customer Input 3
3: Customer Input 4
ISO DO:
Customer Digital Outputs
0: Customer Input 1
1: Customer Input 2
2: Customer Input 3
3: Customer Input 4
Fill:
Reading of Ultrasonic Fill Sensor
•
Old Fill Sensor (2400-2700 mV)
•
New Fill Sensor (4200-3800 mV)
Fill Sol:
Current draw of fill solenoid
•
(0 mA - off)
•
(150-250 mA - on)
Flow/H:
Melt rate of the system
Life Cycles:
total number of pump cycles over life of
system.
Life Weight:
Weight of material dispensed over life of
system.
Pump Sol:
Current draw of pump solenoid
•
(0 mA - off)
•
(150-250 mA - on)
PCB Temp:
PCB Temperature on MZLP1
•
32-16°F (0-71°C)
Pump CPM:
Pump cycles per minute.
USB DL%:
Percentage Complete, only applies when
downloading USB data.
Diagnostic Data