Troubleshooting
3A2592A
23
Cord reel is not providing adequate
ground
Cord is damaged
Use ohmmeter to review ground
path and correct problem.
Cord or reel was installed incor-
rectly
Review installation procedures
beginning on page 8 and correct
problem.
Worn slip-ring /brushes
Replace worn slip-ring/brushes.
See Cord Reel Repair and Parts
manual.
Cord locked when accessory cord
was fully extended
Slip-ring cover is assembled in the
incorrect position
Relocate slip-ring cover in correct
location. See Cord Reel Repair and
Parts manual.
Breaker or fuse trip out (GFCI
accessory or European models
only)
Application does not conform to the
electrical rating of the reel
Check electrical rating on reel label.
Do not attempt to use a reel that is
not rated for the application.
Wires are broken or shorted
Replace all damaged wires.
GFCI models only: power was
removed from unit
Reset GFCI.
Cord could not extend fully
Spring has too much tension
applied
Release some of the spring tension.
See Decreasing Spring Tension,
page 14.
Problem
Cause
Solution