Component Identification
3A1299K
11
Heat Zone and Fluid Control Selection
The tank feed system supports independent tempera-
ture control by utilizing a low power temperature control
module. The system also supports fluid control by utiliz-
ing an FCM. Both the low power temperature control
module and the FCM are located on the electrical panel
within the enclosure.
NOTE: Tank stands are configured for the A (Red)
side. Adjust rotary switch setting if tank is being
used on B (Blue) side.
Adjust Rotary Switch
The rotary switch setting indicates which zone the tem-
perature control module will control in the system. The
low power module and FCM use a 16-position rotary
switch to make selections.
Set the rotary switch to the specific selection according
to the settings listed in the following tables.
Low Power Temperature Control Module Rotary Switch
Settings
FCM Rotary Switch Settings
F
IG
. 4: Electrical Panel
F
IG
. 5: Adjust Rotary Switch
FCM
Low
Power
Temp
Control
r_24C169_3A0395_1a
Rotary Switch
ti12361a
Setting
Zone
0-4
Not Used
5
B (Blue) Tank Heater
6
A (Red) Tank Heater
7
B (Blue) Chiller
8
A (Red) Chiller
9-F
Not Used
Setting
Zone
0-2
Not Used
3
B (Blue) Tank Refill
4
A (Red) Tank Refill
5
Not Used
6-F
Not Used