Troubleshooting
3A1299K
23
Level sensor is not sensing
material when material is
present.
Level sensors out of calibration.
Calibrate level sensor.
Replace level sensor.
Intermittent electrical connections.
Ensure the system main power is ON.
Ensure all electrical connections to the level
sensor are secure. See electrical schematic
in either the HFR or VRM Repair-Parts man-
ual.
Check tank stand circuit breaker in GMS
™
power distribution box to see if it has
tripped. See electrical schematic in either
the HFR or VRM Repair-Parts manual.
FCM errors.
Check FCM circuit breaker in base cube to
see if it has tripped. See electrical schematic
in either the HFR or VRM Repair-Parts man-
ual.
Check FCM. A red LED indicates a problem
with the module. See electrical schematic in
either the HFR or VRM Repair-Parts man-
ual.
Replace FCM.
Problem
Cause
Solution