Setup
4
310798D
Setup
See T
ABLE
1.
* Full load amps with all devices operating at maximum
capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
1.
Locate hose heat control
Position hose heat control for convenient opera-
tor access and maintenance, safe routing of
cables, and easy connections.
2.
Electrical requirements
WARNING
Your system must be grounded. Read warnings, page
3.
Table 1: Electrical Requirements
(kW/Full Load Amps)
Voltage (phase)
Full Load
Peak Amps*
System Watts
230V (1)
15
3500
3.
Connect electrical cord
Power cord is not supplied. Use minimum 12
AWG (3.3 mm
2
), 2 wire + ground.
WARNING
Installing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Have a qualified
electrician connect power and ground to power switch
terminals, see F
. 1. Be sure your installation com-
plies with all National, State and Local safety and fire
codes.
230V, 1 phase: Using 5/32 or 4 mm hex allen
wrench and flat-head screwdriver, connect two
power leads to L1 and L2. Connect green to ground
(GND). See F
. 1.
F
IG
. 1. Connect Electrical Cord
L1 L2
GND
TI5689b