7
308069
Installation
ÄÄ
ÄÄ
Fig. 4
AIR REGULATOR & GAUGE
AIR LINE
QUICK DISCONNECT NIPPLE
QUICK DISCONNECT COUPLER
SPRAY GUN
RAC V
TIP GUARD
GROUND WIRE & CLAMP
purchase separately
16 GALLON DRUM
Note how suction tube curls around the
sides and bottom of the drum.
Â
VENT HOLE
BUNG HOLE
DISPLACEMENT PUMP
HOSE CLAMP
SUCTION TUBE
STRAINER
DRAIN
VALVE
5 GALLON PAIL
BUNG ADAPTER
THUMBSCREW
7550A
Setup for operation
NOTE: Be sure the system has been thoroughly
flushed.
1.
Loosen the hose clamp on the suction hose. Slide
the suction hose as far as possible onto the pump
intake valve.
2.
Slide the clamp up and tighten its screw
snugly! A loose clamp prevents the pump from
getting adequate fluid supply, which results in low
fluid flow and/or spitting air from the gun.
3.
Remove the bung cover from the drum and open
the vent hole.
4.
Loosen the thumbscrew on the bung adapter.
5.
Slide the suction hose and pump through the bung
hole in the drum cover. Before the final positioning
of the pump, screw the bung adapter firmly into the
bung hole. Now position the pump as follows.
a.
For 55 gallon drums: slide the pump into the
drum until you sense that the strainer is at the
bottom of the drum. Tighten the thumbscrew
snugly.
b.
For 16 gallon drums: slide the pump into the
drum and allow the suction hose to curl around
the side and rest on the bottom of the drum.
Tighten the thumbscrew snugly.
c.
For 5 gallon demo pails: Remove the suction
hose and strainer. Install the accessory pail
cover, p/n 222058. Slide the pump into the pail
until the intake valve is 1/2” off the bottom of
the pail. Tighten the bung adapter thumbscrew
snugly.
NOTE: Go to Prime the system on page 9.