background image

13

306–694

Service

DISCONNECTING THE DISPLACEMENT PUMP

WARNING

To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.

1. Flush the pump if possible. Stop the pump at the

bottom of its stroke. 

Relieve the pressure.

2. Disconnect the air and fluid hoses. Remove the

pump from its mounting. Note the relative position
of the pump’s fluid outlet to the air motor’s air inlet.

3. Remove the upper cotter pin (1) and unscrew the

coupling nut (10) from the air motor (16). Unscrew
the tie rod locknuts (3) from the tie rods (9). Care-
fully pull the displacement pump (17) away from
the motor.

4. Loosen the packing nut (R). Loosen the jam nut

(4). Remove the lower cotter pin (1) from the
displacement rod (U). Unscrew the connecting rod
(12) from the displacement rod (U) and from the
coupling (11). See Fig 2.

5. Refer to the separate manual 307–862 for dis-

placement pump service instructions.

6. Refer to the air motor instruction manual supplied

with your pump for air motor service instructions
(307–049 for Standard Bulldog Motors, and
307–304 for Quiet Bulldog Motors).

RECONNECTING THE DISPLACEMENT PUMP

1. Inspect the o–ring (7) on the connecting rod (12)

and replace if necessary. Lubricate the threads of
the connecting rod (12). Insert the coupling (11) in
the coupling nut (10) and screw the coupling onto
the connecting rod (12) so the holes in the cou-
pling align with the top holes in the rod.

2. Screw the connecting rod (12) into the displace-

ment rod (U) until the holes in both parts are
aligned. Install the lower cotter pin (1). Tighten the
jam nut (4) down against the displacement rod (U).
See Fig 2.

3. Orient the pump’s fluid outlet to the air motor’s air

inlet as was noted in step 2 under 

Disconnecting

the Displacement Pump. Position the displace-
ment pump (17) on the tie rods (9).

4. Screw the locknuts (3) onto the tie rods (9) loosely.

Screw the coupling nut (10) onto the air motor
(16). Install the upper cotter pin (1).

5. Mount the pump and reconnect all hoses. Recon-

nect the ground wire if it was disconnected during
repair.

6. Tighten the tie rod locknuts (3) evenly, and torque

to 40–50 ft–lb (54–68 N.m).

7. Tighten the packing nut/wet–cup (R) with the

wrench (5) supplied, so it is just snug – no tighter.
Fill the wet–cup half full with Graco Throat Seal
Liquid or compatible solvent. Start the pump and
run it slowly, at about 20 psi (140 MPa, 1.4 bar) air
pressure, to check that it is operating properly.

16

17

12

5

10

11

1

7

 

9

 3

U

4

8

R

MODEL 217–579

SHOWN

1

AIR INLET

FLUID OUTLET

Fig. 2

1

2

Torque to 40–50 ft-lb

(54–68 N

m)

Lubricate

1

2

1

Содержание 217-579

Страница 1: ...Motor and Severe Duty Displacement Pump Model 221 068 Series A With Quiet Air Motor and Severe Duty Displacement Pump Model 217 579 Series B With Standard Air Motor and Severe Duty Displacement Pump M...

Страница 2: ...nd labels before operating the equipment Use the equipment only for its intended purpose If you are uncertain about usage call your Graco distributor Do not alter or modify this equipment Use only gen...

Страница 3: ...he gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pres sure stop s...

Страница 4: ...ee of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do...

Страница 5: ...grounding continuity 3 Air compressor follow manufacturer s recommen dations 4 Spray gun grounding is obtained through connec tion to a properly grounded fluid hose and pump 5 Object being sprayed ac...

Страница 6: ...required H Surge Tank J Fluid Shutoff Valve K Fluid Pressure Regulator L Spray Gun M Back Pressure Regulator N Director Valve P Fluid Suction Hose Q Suction Tube R Packing Nut Wet Cup S Drain Back Tu...

Страница 7: ...to relieve air trapped between it and the air motor when the valve is closed see the WARNING at left Be sure the bleed valve is easily accessible from the pump and is located downstream from the air r...

Страница 8: ...er safety 2 Shut off the air to the pump 3 Close the bleed type master air valve required in your system 4 Unlock the gun trigger safety 5 Hold a metal part of the gun firmly to the side of a grounded...

Страница 9: ...lves J fluid pressure regulators K and back pressure regulators M are open 3 Place the suction tube Q in the fluid supply 4 Open the bleed type master air valves C WARNING To reduce the risk of splash...

Страница 10: ...ER exceed 100 psi 0 7 MPa 7 bar MAXIMUM AIR PRESSURE to the pump Reduce the air pressure which reduces the fluid outlet pressure if any fluid line accessory is not rated to withstand the maximum worki...

Страница 11: ...r to the separate dis placement pump manual 307 862 Shutdown and Care of the Pump WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressur...

Страница 12: ...nt pump and hose Reprime Check valves need adjustment Adjust see manual 307 862 Packing nut too tight or too loose Adjust see page 11 Worn throat packings Replace see manual 307 862 Pump operates but...

Страница 13: ...connecting rod 12 and replace if necessary Lubricate the threads of the connecting rod 12 Insert the coupling 11 in the coupling nut 10 and screw the coupling onto the connecting rod 12 so the holes...

Страница 14: ...0 ELBOW street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 176 529 LABEL warning not shown...

Страница 15: ...0 ELBOW street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 176 529 LABEL warning not shown...

Страница 16: ...0 ELBOW street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 172 447 LABEL warning not shown...

Страница 17: ...W street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 172 447 LABEL warning not shown 1 16 2...

Страница 18: ...Air Motor Dimensional Drawing OPTIONAL 1 1 2 npt f FLUID INTAKE 42 34 in 1075 5 mm 22 09 in 561 1 mm 2 12 in 53 9 mm Mounting Hole Layout USE GASKET 161 806 4 102 mm 1 375 34 9 mm R Four 0 437 11 1 di...

Страница 19: ...sure bar psi MPa 1 Locate desired flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid outlet pressure curve black Follow left to scale to read fluid outlet pressur...

Страница 20: ...o incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must b...

Отзывы: