background image

20

306–694

Graco Warranty

Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.  With the exception of
any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or
replace any part of the equipment determined by Graco to be defective.  This warranty applies only when the equipment is installed,
operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or
substitution of non-Graco component parts.  Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance or structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect.  If the claimed defect is verified, Graco will repair or replace free of charge any defective parts.  The
equipment will be returned to the original purchaser transportation prepaid.  If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above.  The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available.  Any action for breach of warranty must be brought within two (2) years of the
date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT
NOT MANUFACTURED BY GRACO.
  These items sold, but not manufactured by Graco (such as electric motors, gas engines,
switches, hose, etc.), are subject to the warranty, if any, of their manufacturer.  Graco will provide purchaser with reasonable assistance
in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties
reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures
judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Phone Number

TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:
1–800–367–4023 Toll Free

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Sales Offices: Minneapolis, Detroit, Los Angeles

Foreign Offices: Belgium, Canada, England, Korea, France, Germany, Hong Kong, Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

PRINTED IN U.S.A. 306–694 January 1961, Revised July 1997

Содержание 217-579

Страница 1: ...Motor and Severe Duty Displacement Pump Model 221 068 Series A With Quiet Air Motor and Severe Duty Displacement Pump Model 217 579 Series B With Standard Air Motor and Severe Duty Displacement Pump M...

Страница 2: ...nd labels before operating the equipment Use the equipment only for its intended purpose If you are uncertain about usage call your Graco distributor Do not alter or modify this equipment Use only gen...

Страница 3: ...he gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 8 whenever you are instructed to relieve pres sure stop s...

Страница 4: ...ee of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do...

Страница 5: ...grounding continuity 3 Air compressor follow manufacturer s recommen dations 4 Spray gun grounding is obtained through connec tion to a properly grounded fluid hose and pump 5 Object being sprayed ac...

Страница 6: ...required H Surge Tank J Fluid Shutoff Valve K Fluid Pressure Regulator L Spray Gun M Back Pressure Regulator N Director Valve P Fluid Suction Hose Q Suction Tube R Packing Nut Wet Cup S Drain Back Tu...

Страница 7: ...to relieve air trapped between it and the air motor when the valve is closed see the WARNING at left Be sure the bleed valve is easily accessible from the pump and is located downstream from the air r...

Страница 8: ...er safety 2 Shut off the air to the pump 3 Close the bleed type master air valve required in your system 4 Unlock the gun trigger safety 5 Hold a metal part of the gun firmly to the side of a grounded...

Страница 9: ...lves J fluid pressure regulators K and back pressure regulators M are open 3 Place the suction tube Q in the fluid supply 4 Open the bleed type master air valves C WARNING To reduce the risk of splash...

Страница 10: ...ER exceed 100 psi 0 7 MPa 7 bar MAXIMUM AIR PRESSURE to the pump Reduce the air pressure which reduces the fluid outlet pressure if any fluid line accessory is not rated to withstand the maximum worki...

Страница 11: ...r to the separate dis placement pump manual 307 862 Shutdown and Care of the Pump WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressur...

Страница 12: ...nt pump and hose Reprime Check valves need adjustment Adjust see manual 307 862 Packing nut too tight or too loose Adjust see page 11 Worn throat packings Replace see manual 307 862 Pump operates but...

Страница 13: ...connecting rod 12 and replace if necessary Lubricate the threads of the connecting rod 12 Insert the coupling 11 in the coupling nut 10 and screw the coupling onto the connecting rod 12 so the holes...

Страница 14: ...0 ELBOW street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 176 529 LABEL warning not shown...

Страница 15: ...0 ELBOW street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 176 529 LABEL warning not shown...

Страница 16: ...0 ELBOW street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 172 447 LABEL warning not shown...

Страница 17: ...W street 1 1 2 npt m x 1 npt f 1 9 167 911 ROD tie 7 178 mm shoulder to shoulder 3 10 168 210 NUT coupling 1 11 168 211 COUPLING 1 12 168 212 ROD connecting 1 14 172 447 LABEL warning not shown 1 16 2...

Страница 18: ...Air Motor Dimensional Drawing OPTIONAL 1 1 2 npt f FLUID INTAKE 42 34 in 1075 5 mm 22 09 in 561 1 mm 2 12 in 53 9 mm Mounting Hole Layout USE GASKET 161 806 4 102 mm 1 375 34 9 mm R Four 0 437 11 1 di...

Страница 19: ...sure bar psi MPa 1 Locate desired flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid outlet pressure curve black Follow left to scale to read fluid outlet pressur...

Страница 20: ...o incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must b...

Отзывы: