25
Where
:
N0-E0-Z0: occupied point coordinates
S
:
SD
Z
:
Zenith angle
Az
:
Azimuth angle
IH
:
Instrument
height
TH
:
Target height
【
Procedure of 3D coordinates measurement
】
1. Aim at the target point.
2. Select F2:
【
Meas
】
to start. The coordinate value
of the target is displayed.
3. Press F2:
【
STA
】
to re-input the occupied data if
necessary, see “§6.1 Input the occupied point data”.
4. Press F1:
【
Setup
】
to re-input the target height and
instrument height if necessary, and press F1:
【
MEAS
】
to continue. Follow this operation till all
targets have been measured.
5. Press key
【
ESC
】
to stop EDM measuring, when
EDM mode is“ Continue”, ”Repeat” or “Track”
Azimuth angle
E
N
IH
HD
SD
Z
Target height
Target (N-E-Z)
N0-E0-Z
0
Zenith angle
Vz:
92
°
18' 22"
HR:
0
°
00' 18"
N: cont
m
E:
Z:
Save Meas Mode P1/3
Input I.H. &T.H.
I.H.:
T.H.:
m
B.S. Clear Save Enter