OPERATION

Configuration determines what information is present on the 

LCD display. For instance, total, flowrate, type of calibration, 

etc. 
The Display has been programmed with many features, which 

can be enabled by the end user through the configuration 

process.  By  disabling  unnecessary  features,  day-to-day 

flowmeter  operation  can  be  greatly  simplified,  making  the 

unit easier to use. Alternately, there are several features not 

found in the default configuration.

Available features include:

  •  0 to 3 totals, either resettable (Batch) or non-resettable 

(Cumulative).

  •  Flowrate or no flowrate. Available in units per minute, hour 

or day.

  •  Three different field calibration methods: K-factor entry, 

Dispense/Display or % Correction Factor.

  •  Various units of measure (some or all): GL (gallon), LT 

(litre), IGL (imperial gallon), QT (quart), CF (cubic feet), 

CM (cubic meter), BL (42 gal. barrel), CC (cubic centi-

meter) or OZ (ounce).

Changing Configuration Settings

Access to the configuration settings require a specific pro-

cedure and a pin code available through the GPI Website at 

www.gpimeters.net  or  call  GPI  Customer  Serivce  at  888-

996-3837.

CONFIGURATION

Computer Display

All operations are reflected in the LCD readout. The large center 

digits indicate amounts, where smaller words or “icons” located 

above and below indicate specific information regarding totals, 

flow, calibration and units of measure.
Computer is on continuously while the loop is powered.

Batch and Cumulative Totals

The  computer  maintains  two  totals.  The  Cumulative  Total 

provides continuous measurement and cannot be manually 

reset. The Batch Total can be reset to measure flow during a 

single use. The Cumulative Total is labeled TOTAL 1, Batch 

Total is labeled TOTAL 2 BATCH.
When the Cumulative Total reaches a display reading of 999,999 

the computer will highlight an X10 icon. This indicates to the 

operator that a zero must be added to the 6 digits shown. 

When the next rollover occurs, the computer will highlight an 

X100 icon. This indicates to the operator that two zeros must 

be added to the 6 digits shown.

Press the DISPLAY button briefly to switch between the TOTAL 

1, TOTAL 2 BATCH and FLOWRATE. Press DISPLAY briefly 

to display the TOTAL 2 BATCH. Hold the DISPLAY button for 

3 seconds to reset the Batch Total to zero.
When  fluid  is  flowing  through  the  meter,  a  small  propeller 

icon is highlighted.

Flowrate Feature

To use this feature, press and release DISPLAY until FLOWRATE 

icon appears. The factory set time base will be highlighted to 

the right of FLOWRATE (M = minutes, H = hours, D = days). 

When FLOWRATE is invoked, the display will be indicating 

rate of flow.

Factory and Field Calibration

All calibration information is visible to the user as icons on the 

top line of the display, above the numeric digits.
All  units  are  configured  with  a  “factory”  calibration.  Both 

gallons and liters are available (“GL” or “LT” will be displayed). 

While holding the CALIBRATE button, briefly press DISPLAY 

to toggle between gallons and litres. This factory calibration 

(indicated  with  FAC)  is  permanently  programmed  into  the 

computer and is not user adjustable.
NOTE:    Your  computer  may  have  other  units  of  measure 

programmed into it. If so, holding the CALIBRATE but-

ton and momentarily pressing the DISPLAY button will 

toggle through all factory set units. Other possible units 

are: IGL (imperial gallon), QT (quart), CF (cubic feet), CM 

(cubic meter), BL (42 gal. barrel), CC (cubic centimeter) 

or OZ (ounce).

Switching between different units will not corrupt the Total’s 

contents. For example, in GL mode, the computer totalizes 

10.00 gallons, if the user switches to LT mode, the display will 

read 37.85 litres (the same volume, different unit).
The “field” calibration may be set by the user, and can be 

changed or modified at any time using the calibration procedure 

described in the Calibration Section. Totals derived from the 

field calibration are invoked when the FAC icon is no longer 

visible on the top line of the display.

CALIBRATION

Field Calibration Procedures

(K-Factor Method)

If  the  display  was  purchased  as  an  accessory  or  remote, 

then the field calibration method set at the factory is K-factor 

Entry method.
This method allows the user to key in a single point K-factor 

value that represents the meter it will be used with. K-factor 

values for specific meters can be found on the meter itself, 

in Table 1 or www.gpimeters.net.
1.  To field calibrate, press and hold both CALIBRATE and 

DISPLAY  buttons  for  about  3  seconds  until  you  see 

FLdCAL. Release both buttons and you will see Kxxxx.x 

(where “x” represents the current field-cal k-factor value). 

You are now in the field calibration mode.

Содержание GM001

Страница 1: ...CONTENTS To the owner Congratulations on receiving your GPI 4 20 mA Out with Display We are pleased to provide you with a product designed to give you maximum reliability and efficiency Our business i...

Страница 2: ...in indoor or outdoor applications where occasional exposure to moisture is common The 4 20 mA Out with Display is available in two ver sions One indicates flowrate in units minute and one in units ho...

Страница 3: ...her liquids occasional low pressure splashing will not harm unit if cable entry points are well sealed subject to 5g shock loading facing the sun directly for long periods of time close to high voltag...

Страница 4: ...m ONLY Local Com HL HF IN R See note EDM Power INPUTS OUTPUTS 4 20 mA Out with Display Loop Loop current current Min V 8 5 Max V 35 Customer Equipment Minimum signal amplitude required for normal oper...

Страница 5: ...Max V 35 Customer Equipment Loop Power Supply Typ 12 24 VDC Loop Input Loop Input NOTE 1 Loop power supply electrically isolated from customer equipment NOTE 2 Actual value of loop current mA is disre...

Страница 6: ...Frequency Generating Input Device INPUTS OUTPUTS 4 20 mA Out with Display Loop Loop current current Customer Equipment Loop Power Supply Typ 12 24 VDC Open Collector Pulse In Pulse In Return Pulse Ou...

Страница 7: ...that the enclosure sealisnotcrimpedortwisted Donotover tightencornerscrews hand tighten only Faceplate can be rotated 90 W I R I N G D I A G R A M 8 4 20 mA or 0 20 mA Output Customer Equipment Witho...

Страница 8: ...4 20 mA and Pulse Output option available only with Reed Switch input W I R I N G D I A G R A M 1 0 4 20 mA or 0 20 mA Output and Pulse Output Customer Equipment With Built in Power Supply Input Reed...

Страница 9: ...button for 3 seconds to reset the Batch Total to zero When fluid is flowing through the meter a small propeller icon is highlighted Flowrate Feature Tousethisfeature pressandreleaseDISPLAYuntilFLOWRA...

Страница 10: ...ser to tweak the factory calibration by a percent that represents application fluid or plumbing differences 1 To calibrate press and hold the CALIBRATE and DISPLAY buttonsforabout3secondsuntilyouseeFL...

Страница 11: ...the transmitter If signal is being received deactivate it by one of the following methods Stop the flow through the line that is being recorded Disconnect the output device on the flowmeter Locking U...

Страница 12: ...presently operating temporarily disable its external power supply Be sure to allow at least 30 seconds to elapse with unit unpowered 2 Press and hold the 4 button While holding watch the indicator li...

Страница 13: ...signal input connections for intermittent open or short circuits F LOOP OUTPUT 1 Output response time setting too long Select a shorter response time setting STABLE BUT especially for fast input sign...

Страница 14: ...14 DIMENSION DRAWINGS...

Страница 15: ...Tapping GM001 GM002 and GM003 2 9 120058 01 Bracket 1 10 904005 13 Screw 6 32 x 1 2 in 4 Item No No Part No Description Req d 11 904002 44 Screw 8 32 x 5 16 in 2 12 125066 20 Cable 20 ft 1 125066 3 C...

Страница 16: ...linearity plus span any input loop current output 0 C to 70 C loop voltage supply 12 VDC to 24 VDC 0 5 of span plus possible resolution uncertainty Max Conversion Resolution Uncertainty Loop current o...

Страница 17: ...gital Pulse Out Open Collector square wave Will switch up to 60 V and up to 200 mA Closed circuit voltage drop typically 0 1 V guaranteed less than 0 5 V at any in range current Configuration 2 Totals...

Страница 18: ...Please contact GPI before returning any part It may be possible to diagnose the trouble and find a solution with a telephone call GPI can also inform you of any special require ments you will need to...

Страница 19: ......

Страница 20: ...rranty shall not apply if A the product has been altered or modified outside the warrantor s duly appointed representative B the product has been subjected to neglect misuse abuse or damage or has bee...

Отзывы: