![Gotting HG G-98830 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/gotting/hg-g-98830/hg-g-98830_operating-manual_2247547073.webp)
Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
73
Configuration of the System via the Service Interface – Chapter 10
Within 50 seconds, you must start the XMODEM transfer of the file on the host as
follows:
Choose
Transfer > Send file> XMODEM > Select file
from the menu.
After a successful transmission the message
Success
is output. The antenna
has checked the file and loaded it into the parameter RAM.
To save the values permanently in the antenna, you have to proceed as described in
chapter 10.2.14 „(L)oad values to EEProm“ on page 71.
To export a data set from the antenna to the host:
Press the key
.
The XMODEM-file transfer starts.
Alternatively, you can export the data using the HyperTerminal monitor program as
follows:
Choose
Transfer > Receive file> XMODEM > Select folder
from the menu and
enter a file name.
After a successful transfer, the message
Success
is output.
10.2.17 P(r)int Parameters
With
P(r)int Parameters
you can display the system parameters and archive them by
recording them (e.g. with the monitor program in HyperTerminal).
To archive the system parameters from the main menu:
Press the key
.
The instruction
Activate file recording
is shown.
In order to archive the parameters:
Select in the terminal program (here: HyperTerminal menu
Transfer > Capture
data
and specify a file name.
Press any key.
The values are output and saved by HyperTerminal.
Terminate the recording in HyperTerminal in the menu
Transfer > Capture Data
> stop.