![Gotting HG G-98830 Скачать руководство пользователя страница 98](http://html1.mh-extra.com/html/gotting/hg-g-98830/hg-g-98830_operating-manual_2247547098.webp)
Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
98
Chapter 16 – Appendix
16.5.18 Codes Relevant in CANopen® for System Configuration
16.5.19 Manufacturer Parameters – Node Parameters
Table 52
CANopen® directory: Relevant codes for the system configuration
Value
Name
Description
0x0001
HILOW
Changes the sequence within multi-byte values
0x0002
CODE_SELECT Select code channel (see 10.2.6 „(T)ime & Code“ on
0x0004
0x0008
0x0010
POSI_TIMED
Time or level controlled positioning pulse (see
10.2.6 „(T)ime & Code“ on page 56)
0x0020
0x0040
0x0080
0x0100
0x0200
POSI_MASK
One positioning pulse per transponder crossing
(see 10.2.6 „(T)ime & Code“ on page 56)
0x0400
AUTO_TUNE
see 10.2.7 „(F)requency & Antenna Tuning“ on page
60
0x0800
0x1000
0x2000
POSI_TRNSP
Positioning pulse after decoding
(see 10.2.6 „(T)ime & Code“ on page 56)
0x4000
0x8000
0x10000
AUTOSTART
If set, the node starts in
Operational
mode (see
10.2.9 „CA(N)-Open-Parameters“ on page 65)
Table 53
CANopen® directory: Manufacturer parameters - node parameters
Index Subindex Name
Type
Attr. Map Default Description
0x20
01
00
number of
parameter
Unsigned 8 RO No
0x02
number of subindexes
01
Node baud
rate
Unsigned 8 RW No
0x04
125 kBaud according to Table
54 below *)
02
Node ID
Unsigned 8 RW No
0x01
Node address 1 *)
*) After changing these parameters, you must save the changes with <save all> and trigger a node
reset.