Device Description HG G-7335xZA | English, Revision 05 | Date: 19.02.2020
38
Chapter 8 – CAN Interface (HG G-73350)
8.5.4.8 Restore Default Parameter
By writing the signature load“ in ASCII code (hex code: 0x64616F6C) or “daol“ (hex
code: 0x6C6F6164) on sub index 1, 2 respectively 4 the corresponding default pa
-
rameters are loaded. A reset is recommended.
8.5.4.9 Producer Heartbeat Time
When entering 0 as time, this function is deactivated.
8.5.4.10 Identity Object
Table 35
CAN: Restore Default Parameter
Index
Sub Index Name
Format
Attr. Map Default
Meaning
0x1011 00
Restore
Parameter
Unsigned 8
RO
No
0x04
number of sub
indexes
01
Restore All
Unsigned 32 RW
No
0x00000001 Restore All is possi
-
ble
02
Restore Com
-
munication
Unsigned 32 RW
No
0x00000001 Restore Communi
-
cation is possible
04
Restore Man
-
ufacture
Unsigned 32 RW
No
0x00000001 Restore Manufac
-
ture is possible
Table 36
CAN: Producer Heartbeat Time
Index
Sub Index Name
Format
Attr. Map Default
Meaning
0x1017 00
Producer
Heartbeat
Time
Unsigned 16 RW
No
1000
Heartbeat time in
ms (ca.)
Table 37
CAN: Identity Object
Index
Sub Index Name
Format
Attr. Map Default
Meaning
0x1018 00
Identity
Object
Unsigned 8
RO
No
0x03
number of sub
indexes
01
Vendor ID
Unsigned 32 RO
No
0x00000202 manufacturer
number, deter
-
mined by CiA
02
Product Code Unsigned 32 RO
No
0x00073350 name of the device
03
Revision
Unsigned 32 RO
No
0x00000001 revision of the
device
04
Serial Num
-
ber
Unsigned 32 RO
No
73.....
7-digit serial num
-
ber of the device