PA SERIES
OM-06622
PAGE B - 1
INSTALLATION
INSTALLATION - SECTION B
Review all SAFETY information in Section A.
Since pump installations are seldom identical, this
section offers only general recommendations and
practices required to inspect, position, and ar
range the pump and piping.
Most of the information pertains to a standard
static lift
application where the pump is positioned
above the free level of liquid to be pumped.
If installed in a
flooded suction application
where
the liquid is supplied to the pump under pressure,
some of the information such as mounting, line
configuration, and priming must be tailored to the
specific application. Since the pressure supplied
to the pump is critical to performance and safety,
be sure
to limit the incoming pressure to 50% of the
maximum permissible operating pressure as
shown on the pump performance curve.
For further assistance, contact your Gorman‐Rupp
distributor or the Gorman‐Rupp Company.
Pump Dimensions
See Figure 1 for the approximate physical dimen
sions of this pump.
OUTLINE DRAWING
Figure 1. Pump Model PA6D60-4045T
PREINSTALLATION INSPECTION
The pump assembly was inspected and tested be
fore shipment from the factory. Before installation,
inspect the pump for damage which may have oc
curred during shipment. Check as follows:
a. Inspect the pump for cracks, dents, damaged
threads, and other obvious damage.
b. Check for and tighten loose attaching hard
ware. Since gaskets tend to shrink after dry
ing, check for loose hardware at mating sur
faces.
Содержание PA6D60-4045T
Страница 22: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model PA6D60 4045T...
Страница 24: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46143 155 Power Unit Kit...
Страница 26: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION Figure 3 PA6D60 SAE 3 10 COMM Pump Assembly...
Страница 28: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 8 ILLUSTRATION Figure 4 46133 416 Pump End Assembly...
Страница 30: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 10 ILLUSTRATION Figure 5 44163 549 Repair Rotating Assembly...