PA SERIES
OM-06622
MAINTENANCE & REPAIR
PAGE E - 16
moved from the pump before lifting. Lift
the pump or component only as high as
necessary and keep personnel away
from suspended objects.
Use
only
replacement parts provided or
approved by Gorman‐Rupp. Use of non‐
authorized parts may result in damage to
the equipment and/or injury to personnel
and
will
invalidate the warranty
.
Priming Chamber Removal And Disassembly
(Figure 6)
Disconnect the air discharge tubing from the prim
ing chamber assembly (1). Support the priming
chamber assembly using a sling and a suitable lift
ing device. Remove the hardware (6 and 7) and
separate the priming chamber assembly, gasket
(8) and baffle (9) from the suction spool (5, Figure
4).
(Figure 7)
Remove the hardware (2 and 3) securing the prim
ing valve (1) to the priming chamber (5). Carefully
lift the valve components from the priming cham
ber. Remove the gasket (4) and clean the mating
surfaces.
If the priming valve float is stuck or the strainer (6) is
clogged, it can usually be cleaned without further
disassembly.
The only serviceable part of the priming valve is the
orifice button (not shown). If liquid continues to by
pass through the priming chamber after adjusting
the orifice button (see
Priming Chamber Reas
sembly and Installation
for adjustment), the but
ton may require replacement. To replace the orifice
button, remove one of the “e‐clips” from the pivot
pin closest to the orifice button and remove the piv
ot pin. This will allow the linkage to be raised high
enough to access the orifice button.
Remove the hex nut and lock washer securing the
orifice button to the linkage bar and unscrew the
orifice button from the linkage bar.
Discharge Check Valve Removal and
Disassembly
(Figure 3)
Remove the hardware (not shown) securing the
discharge check valve bracket to the base.
Support the discharge check valve (3) using a sling
and a suitable lifting device. Remove the hardware
(4, 5, 6 and 8) and separate the discharge check
valve assembly and gasket (7) from the pump as
sembly (1).
The flapper and gasket are the only serviceable
parts of the check valve. If the flapper requires re
placement, remove the hardware securing the
cover and gasket. Separate the valve cap and re
move the flapper.
Suction Spool and Wear Plate Removal
(Figure 4)
The wear plate (3) is easily accessible and may be
serviced by removing the suction spool (2). Before
attempting to service the pump, remove the pump
casing drain plug (4) and drain the pump. Clean
and reinstall the drain plug.
Support the suction spool using a suitable hoist
and sling.
Remove the back cover nuts (19). Remove the se
curing hardware (11 and 21), adjusting screws
(18) and locking collars (20) from the studs (17).
Pry the suction spool and assembled wear plate
from the pump casing (1).
NOTE
An alternate method of removing the suction spool
from the pump casing is to remove the back cover
nuts (19) and two diagonally opposing locking col
lars (20). Use the adjusting screws (18) to press the
suction spool out of the pump casing.
Inspect the wear plate for excessive wear or scor
ing. If replacement is required, or if the O‐rings (13
and 14) require replacement, remove the hard
ware (15 and 16) and separate the wear plate from
the suction spool.
Remove and discard the O‐rings (6A, 13 and 14).
Содержание PA6D60-4045T
Страница 22: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model PA6D60 4045T...
Страница 24: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46143 155 Power Unit Kit...
Страница 26: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION Figure 3 PA6D60 SAE 3 10 COMM Pump Assembly...
Страница 28: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 8 ILLUSTRATION Figure 4 46133 416 Pump End Assembly...
Страница 30: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 10 ILLUSTRATION Figure 5 44163 549 Repair Rotating Assembly...