GORMAN-RUPP PA6D60-4045T Скачать руководство пользователя страница 10

PA SERIES

OM-06622

PAGE B - 3

INSTALLATION

If the pump has been mounted on a mov­
able base, do not attempt to operate the
pump unless the unit is level. Be sure
the leveling stands are positioned on a
solid surface, and the wheels are
chocked.

SUCTION AND DISCHARGE PIPING

Pump performance is adversely effected by in­
creased suction lift, discharge elevation, and fric­
tion losses. See the performance curve and oper­
ating range shown on Page E‐1 to be sure your
overall application allows pump to operate within
the safe operation range.

Materials

Either pipe or hose maybe used for suction and
discharge lines; however, the materials must be
compatible with the liquid being pumped. If hose is
used in suction lines, it must be the rigid‐wall, rein­
forced type to prevent collapse under suction. Us­
ing piping couplings in suction lines is not recom­
mended.

Line Configuration

Keep suction and discharge lines as straight as
possible to minimize friction losses. Make mini­
mum use of elbows and fittings, which substan­
tially increase friction loss. If elbows are necessary,
use the long‐radius type to minimize friction loss.

Connections to Pump

Before tightening a connecting flange, align it ex­
actly with the pump port. Never pull a pipe line into
place by tightening the flange bolts and/or cou­
plings.

Lines near the pump must be independently sup­
ported to avoid strain on the pump which could
cause excessive vibration, decreased bearing life,
and increased shaft and seal wear. If hose‐type
lines are used, they should have adequate support

to secure them when filled with liquid and under
pressure.

Gauges

The pump is drilled and tapped for installing dis­
charge pressure and vacuum suction gauges. It is
recommended that gauges be installed to monitor
pump performance. Seal the gauge threads with
pipe dope to ensure an airtight seal. Follow the
sealant manufacturer's recommendations when
selecting and applying the pipe dope. The pipe
dope should be compatible with the liquid being
pumped.

SUCTION LINES

To avoid air pockets which could affect pump prim­
ing, the suction line must be as short and direct as
possible. When operation involves a suction lift, the
line must always slope upward to the pump from
the source of the liquid being pumped; if the line
slopes down to the pump at any point along the
suction run, air pockets will be created.

Fittings

Suction lines should be the same size as the pump
inlet. If reducers are used in suction lines, they
should be the eccentric type, and should be in­
stalled with the flat part of the reducers uppermost
to avoid creating air pockets. Valves are not nor­
mally used in suction lines, but if a valve is used,
install it with the stem horizontal to avoid air pock­
ets.

Strainers

Be certain to use the strainer furnished with the
pump; any spherical solids which pass through the
strainer will also pass through the pump itself.

If a strainer not furnished with the pump is installed
by the pump user, make certain that the total area
of the openings in the strainer is at least three or
four times the cross section of the suction line, and
that the openings will not permit passage of solids
larger than the solids handling capability of the
pump.

This pump is designed to handle up to 3 inch (76,2
mm) diameter spherical solids.

Содержание PA6D60-4045T

Страница 1: ...OM 06622 02 June 16 2014 ACDEU GORMAN RUPP PUMPS www grpumps com 2014 Gorman Rupp Pumps Printed in U S A INSTALLATION OPERATION AND MAINTENANCE MANUAL WITH PARTS LIST PA SERIES PUMP MODEL PA6D60 4045T...

Страница 2: ...ERIAL NUMBER Please record your pump model and serial number in the spaces provided below Your Gorman Rupp distributor needs this information when you require parts or service Pump Model Serial Number...

Страница 3: ...ttings PAGE B 3 Strainers PAGE B 3 Sealing PAGE B 4 Suction Lines in Sumps PAGE B 4 Suction Line Positioning PAGE B 4 DISCHARGE LINES PAGE B 5 Siphoning PAGE B 5 Valves PAGE B 5 ALIGNMENT PAGE B 5 AUT...

Страница 4: ...l PAGE C 18 Separating Pump And Drive Assembly From Engine PAGE C 19 Draining Oil From Seal Cavity PAGE C 19 Loosening Impeller PAGE C 19 Pump Casing Removal PAGE C 20 Impeller Removal PAGE C 20 Seal...

Страница 5: ...ed in this manual or in other lit erature accompanying the unit please contact your Gorman Rupp distributor or the Gorman Rupp Company The Gorman Rupp Company P O Box 1217 Mansfield Ohio 44901 1217 Ph...

Страница 6: ...olatile non flammable liquids containing specified entrained solids Do not attempt to pump volatile corro sive or flammable liquids which may damage the pump or endanger person nel as a result of pump...

Страница 7: ...ed Use caution when positioning the skid mounted unit to prevent damage to the fuel tank Do not operate an internal combustion engine in an explosive atmosphere When operating an internal combustion e...

Страница 8: ...the pressure supplied to the pump is critical to performance and safety be sure to limit the incoming pressure to 50 of the maximum permissible operating pressure as shown on the pump performance cur...

Страница 9: ...nals and clamps may be coated with petroleum jelly to retard corro sion Connect and tighten the positive cable first then the negative cable POSITIONING PUMP Death or serious personal injury and damag...

Страница 10: ...t to secure them when filled with liquid and under pressure Gauges The pump is drilled and tapped for installing dis charge pressure and vacuum suction gauges It is recommended that gauges be installe...

Страница 11: ...ll a baffle between the inflow and the suction inlet at a distance 1 1 2 times the diameter of the suction pipe The baffle will allow entrained air to escape from the liquid before it is drawn into th...

Страница 12: ...it is recommended that a throttling valve be installed in the discharge line to protect the pump from excessive shock pres sure and reverse rotation when it is stopped If the application involves a h...

Страница 13: ...and pipe is available attach the float switch cable to the standpipe in the sump at the approxi mate desired liquid level b In a single float system the cable can be teth ered to the suction line or s...

Страница 14: ...e LUBRICATION in MAINTENANCE AND REPAIR The pump will begin to prime upon startup The air in the suction line will be discharged from the educ tor discharge line Complete priming is indicated by a pos...

Страница 15: ...d Overheating The maximum liquid temperature for this pump is 160 F 71 C Do not apply it at a higher operating temperature Overheating can occur if operated with the valves in the suction or discharge...

Страница 16: ...mperatures by hand is inaccu rate Bearing temperatures can be measured ac curately by placing a contact type thermometer against the housing Record this temperature for future reference A sudden incre...

Страница 17: ...ollapsed Replace suction hose Leaking or worn seal or pump gasket Check pump vacuum Replace leaking or worn seal or gasket Air compressor head 180 out Consult factory Air compressor damaged or belts b...

Страница 18: ...ow rate and run engine at maximum governed speed Discharge flow too slow Dilute if possible Suction check valve or foot valve clogged or binding Clean valve Suction intake not submerged at proper leve...

Страница 19: ...e schedule will help assure trouble free performance and long life from your Gorman Rupp pump For specific questions con cerning your application contact your Gorman Rupp distributor or the Gorman Rup...

Страница 20: ...mpeller Clearance Seal Plate I Check Valve I Pressure Relief Valve If So Equipped C Pump and Driver Alignment I Shaft Deflection I Bearings I Bearing Housing I Piping I Driver Lubrication See Mfgr s L...

Страница 21: ...el with minimum suction lift Since pump installations are seldom identical your performance may be dif ferent due to such factors as viscosity specific gravity elevation temperature and impeller trim...

Страница 22: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model PA6D60 4045T...

Страница 23: ...L CODE QTY 1 PUMP END ASSY PA6D60 SAE 3 10 COMM 1 2 POWER UNIT KIT 46143 155 1 3 BATTERY SEE OPTIONS 1 4 PUMP MOUNTING KIT 48157 016 1 NOT SHOWN PRIME AIRE DECAL 38812 078 2 INSTRUCTION TAG 38817 085...

Страница 24: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46143 155 Power Unit Kit...

Страница 25: ...15 HOSE CLAMP 26518 641 2 16 HOSE 11308G 1 17 FLAT WASHER K10 15991 8 18 HEX HEAD CAP SCREW B1008 15991 4 19 LOCK WASHER J10 15991 4 20 HEX NUT D10 15991 4 21 CONNECTOR 26351 065 1 22 PIPE TEE U08 119...

Страница 26: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION Figure 3 PA6D60 SAE 3 10 COMM Pump Assembly...

Страница 27: ...213 15991 6 5 LOCK WASHER J12 15991 6 6 HEX NUT D12 15991 8 7 GASKET 25113 036 1 8 HEX HEAD CAP SCREW B1212 15991 2 9 DRIVE ASSY 44162 159 1 10 SUCTION SUPPORT BRACKET 34266 041 15080 1 11 FLAT WASHER...

Страница 28: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 8 ILLUSTRATION Figure 4 46133 416 Pump End Assembly...

Страница 29: ...EAD CAP SCREW B0806 15991 4 11 LOCK WASHER J08 15991 4 11A LOCK WASHER J08 15991 4 12 PIPE PLUG P08 15079 1 13 O RING 25154 449 1 14 O RING 25154 265 1 15 LOCK WASHER J06 15991 7 16 HEX NUT D06 15991...

Страница 30: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 10 ILLUSTRATION Figure 5 44163 549 Repair Rotating Assembly...

Страница 31: ...79 1 13 HEX HD CAPSCREW B0805 1 2 15991 4 14 LOCKWASHER J08 15991 4 15 HEX HD CAPSCREW 21632 938 15991 6 16 LOCKWASHER J06 15991 6 17 OIL SEAL S1907 1 18 DRIVE FLANGE 38545 020 10000 1 19 INTERM GUARD...

Страница 32: ...NAME PART NUMBER MAT L CODE QTY 1 PRIMING CHAMBER ASSY 46112 709 1 2 PIPE BUSHING AP1608 11999 1 3 STREET ELBOW RS08 11999 1 4 BALL VALVE 26631 052 1 5 STUD C0809 15991 4 6 HEX NUT D08 15991 4 7 LOCK...

Страница 33: ...LIST ITEM NO PART NAME PART NUMBER MAT L CODE QTY 1 PRIMING VALVE 26664 007 1 ORIFICE BUTTON 26688 021 1 2 HEX HD CAPSCREW B0806 15991 8 3 LOCKWASHER J08 15991 8 4 PRIMING VALVE GASKET 38683 657 19060...

Страница 34: ...SY 44165 016 1 2 BUSHING 24131 498 1 3 KEY 24113 603 1 4 DRIVE FLANGE 38545 004 10000 1 5 LOCK WASHER 21171 536 8 6 SOCKET HEAD CAP SCREW 22644 220 8 6 SOCKET HEAD CAP SCREW BD0606 1 2 15991 8 7 CAP S...

Страница 35: ...which could be dangerous to personnel How ever this manual cannot possibly antici pate and provide detailed instructions and precautions for every situation that might occur during maintenance of the...

Страница 36: ...button Remove the hex nut and lock washer securing the orifice button to the linkage bar and unscrew the orifice button from the linkage bar Discharge Check Valve Removal and Disassembly Figure 3 Remo...

Страница 37: ...1 4 liters minimum capacity under the seal cavity drain plugs 12 Figure 4 and 8B Figure 5 Remove the plugs and drain the oil from the seal cavity into the container For shorter drain time remove the v...

Страница 38: ...ng 9 Position the seal plate on a flat surface with the impeller side down Use a wooden dowel or other suitable tool to press on the back side of the stationary seat until the seat and O ring can be r...

Страница 39: ...bearings as indicated in Shaft And Bearing Removal And Disassembly To prevent damage during removal from the shaft it is recommended that bearings be cleaned and inspected in place It is strongly rec...

Страница 40: ...BRICA TION at the end of this section Seal Reassembly and Installation Figures 5 and 10 Clean the seal cavity and shaft with a cloth soaked in fresh cleaning solvent Most cleaning solvents are toxic a...

Страница 41: ...cover the threads with electrical or duct tape Slide the O ring over the shaft until it seats against the shaft shoulder Remove the tape covering the threads Check to ensure that the shaft threads ar...

Страница 42: ...collars 20 adjusting screws 30 and back cover nuts 19 onto the studs Tighten the back cover nuts evenly in an al ternating pattern to press the suction spool into the pump casing until the wear plate...

Страница 43: ...ribed above to obtain the proper face clearance Pump Casing Installation Figure 4 Lubricate the rotating assembly O rings 6 and 8 with a light coating of grease Use a suitable hoist and sling to slide...

Страница 44: ...Priming Chamber Removal and Disassembly for orifice button removal If the orifice button was removed screw the new orifice button into the linkage bar until fully seated Align the hole in the linkage...

Страница 45: ...When lubricating a dry overhauled bearing hous ing fill the bearing cavity with approximately 40 ounces 1 2 liters of oil Clean and reinstall the air vent Do not over lubricate Over lubrication can ca...

Страница 46: ...For Warranty Information Please Visit www grpumps com warranty or call U S 419 755 1280 Canada 519 631 2870 International 1 419 755 1352 GORMAN RUPP PUMPS...

Отзывы: