PA SERIES
OM-06622
PAGE B - 5
INSTALLATION
Figure 2. Recommended Minimum Suction Line Submergence vs. Velocity
DISCHARGE LINES
Siphoning
Do not terminate the discharge line at a level lower
than that of the liquid being pumped unless a si
phon breaker is used in the line. Otherwise, a si
phoning action causing damage to the pump
could result.
Valves
This pump is designed with a check valve in the
discharge line.
If a throttling valve is desired in the discharge line,
use a valve as large as the largest pipe to minimize
friction losses. Never install a throttling valve in a
suction line.
With high discharge heads, it is recommended that
a throttling valve be installed in the discharge line
to protect the pump from excessive shock pres
sure and reverse rotation when it is stopped.
If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.
ALIGNMENT
The alignment of the pump, air compressor and
engine is critical for trouble‐free mechanical opera
tion. See Section E,
Securing Intermediate And
Drive Assembly To Engine
in
MAINTENANCE
AND REPAIR
, for details.
AUTO‐START
The standard pump is equipped with an auto‐start
control system which allows the pump to start and
stop as the liquid level in the wet well or sump rises
and falls.
Refer to the information which follows for installa
tion details for the liquid level sensing system pro
vided with your pump.
Содержание PA6D60-4045T
Страница 22: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 2 PARTSPAGE ILLUSTRATION Figure 1 Pump Model PA6D60 4045T...
Страница 24: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 4 ILLUSTRATION Figure 2 46143 155 Power Unit Kit...
Страница 26: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 6 ILLUSTRATION Figure 3 PA6D60 SAE 3 10 COMM Pump Assembly...
Страница 28: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 8 ILLUSTRATION Figure 4 46133 416 Pump End Assembly...
Страница 30: ...OM 06622 PA SERIES MAINTENANCE REPAIR PAGE E 10 ILLUSTRATION Figure 5 44163 549 Repair Rotating Assembly...