OM-06617
SE SERIES
3
INSTALLATION
INSTALLATION
Review all SAFETY information in Section A.
Do not operate this pump where explo
sive vapors or flammable material exist.
Death or serious injury will result.
Pumps and related equipment must be in
stalled and operated according to all na
tional, local and industry standards.
PREINSTALLATION INSPECTION
Before installation, inspect the pump for damage
which may have occurred during shipment. Check
as follows:
a. Inspect the pump assembly for cracks, dents,
damaged threads, and other obvious dam
age.
b. Check for and tighten loose attaching hard
ware.
c. The pump is furnished with a 50‐foot (15 me
ter) long power cable. Inspect the cable for
cuts or damage.
d. Carefully read all tags, decals, and markings
on the pump assembly, and perform all duties
as indicated.
If anything appears to be abnormal, contact your
Gorman‐Rupp distributor to determine the repair
or updating policy.
Do not
put the pump into serv
ice until appropriate action has been taken.
PUMP INSTALLATION
Lifting
Pump unit weights will vary depending on the mod
el. Check the shipping tag on the unit packaging
for the actual weight. Drain the pump and remove
all customer‐installed equipment such as dis
charge hoses or piping before attempting to lift ex
isting, installed units.
If necessary, attach a rope or chain to the lifting
handle on the top of the pump.
Do not
lift the unit
by the power cable or the discharge piping. Cus
tomer‐installed equipment such as rigid discharge
piping
must
be removed before attempting to lift.
Figure 1. Do Not Lift Pump by Power Cable
Do not attempt to lift the pump by the
power cable or piping. Attach proper
lifting equipment to the handle on the
pump.
Installation
Before installing the pump, clear the sump basin of
any debris or sediment. See Figure 4 for a typical
pump installation.
The sump basin must be vented in ac
cordance with local plumbing codes.
Do not operate this pump where explo
sive vapors or flammable material exist.
Death or serious injury will result.
Содержание SE Series