LOCKING/UNLOCKING OF THE DOORS

The system operates the door locks, locking them during arming and unlocking them when disarm-

ing the system.

Besides, the system is able to lock the doors automatically upon the ignition activation and to unlock 

them after ignition shut-off, if these operations are allowed by the programming (sublevels 7.2, 7.3).

If you need to unlock the doors when ignition is active – shortly press the “VALET” button.

COMPARTMENT LIGHT DELAY

If the option of the compartment light turning off delay is allowed by the programming (sublevel 3.5) 

then the system arms door unlocking sensors 15 seconds upon the doors closing. At that the system 
does not produce any sonic signal if a door was not closed during the system arming.

 VEHICLE TRACING

Pressing of the remote’s button “1” in security mode activates the vehicle tracing function. The sys-

tem produces a single light and double sonic signal and then returns to the security mode.

“PANIC” MODE

Regardless of whether the system is armed, armed with a running engine or disarmed, the simulta-

neous pressing of the remote’s buttons “1” & “2” will activate the “Panic” function - the system produces 

the light and sonic alarm signals and also sends alarm message to the pager.

If the system is disarmed and the engine is running, then turn the system to the perimeter security 

mode with a running engine to activate the “Panic” mode. That is to say, to activate the “Panic” mode in 

this case you have to:

- press and then release the remote’s button “2”;

- press and then release the remote’s button “1”;

- press and hold buttons “1” & “2” of the remote control unit simultaneously;

- release buttons “1” & “2” upon the “Panic” mode activation;

Generation of the sonic signals in “Panic” mode can be cancelled by programming (sublevel 3.2). 

Moreover, a message transmitting to the pager can be allowed by the programming (sublevel 6.6).

Press any button of the remote unit to exit “Panic” mode. The system turns to the security mode even 

if it was disarmed at the moment of the “Panic” mode activation.

 TIMER CHANNEL #1

Timer channel #1 is designed to perform one extra option, subject to your choice. Algorithm of this 

channel is set during the system programming (level 5). The channel can be activated during arming, dis-
arming and by simultaneous pressing of the buttons “1” & “3” of the remote control. Duration of the signal 
on the timer channel #1 is set during programming.

During the time of the timer channel #1 work as well as within 10 seconds upon its cessation, the 

system does not respond to the status of the shock and volume sensors.

You can apply the channel #1 for one of the following purposes:
- dim light turning on during the arming;
- the compartment timed lighting during the disarming;

TIMER CHANNEL #2

ТTimer channel is designed to control the work of the hood or trunk lock. The channel is activated by 

the remote’s button “3”. Signal duration appearing on the channel #2 is 1 second.

If the channel #2 has been activated during security mode then, during the time of its work and within 

the 10 seconds upon its cessation the system, still staying armed, does not respond to the status of the 
shock sensor and the limit switch of the hood or trunk. If within this period of time neither hood nor trunk 

Содержание G303

Страница 1: ...Gorgon G3O3...

Страница 2: ...ssenger compartment light activation delay 8 Car tracing feature 8 Panic mode 8 Timer channel 1 8 Timer channel 2 8 Distant radio alert channel 9 System control via a secret code 9 Technical maintenan...

Страница 3: ...ccumulator led out to the mass ground The system complies with the climatic requirements U 2 1 N 2 1 according to GOST 15150 69 standard and is intended for the use within the environment temperature...

Страница 4: ...security mode Not more than 20 Main unit supply voltage V 9 15 Radio channel frequency Hz 433 92 Frequency deviation Hz 433 075 Hz to 434 79 MHz Emission power Wt Less than 10 Operative temperature ra...

Страница 5: ...er than 1 5sec 1 Arming with a built in shock sensor deactivation Two signals of the parking lights 1 pause not longer than 1 5sec 3 Arming with an external double area sensor deactivation Three signa...

Страница 6: ...area sensors deactivation perimeter se curity press button 1 of the remote unit release it within a 1 5 seconds period and then press buttons 1 3 simultaneously The system will produce four signals of...

Страница 7: ...arm mode and to stop generating all alert signals just press any button of the remote control unit If the warning level of the system s sensor has been activated three times consequently the system wi...

Страница 8: ...ess and then release the remote s button 1 press and hold buttons 1 2 of the remote control unit simultaneously release buttons 1 2 upon the Panic mode activation Generation of the sonic signals in Pa...

Страница 9: ...cret code you have an option to switch between the following system modes from armed or alert modes to disarmed mode from immobilizer turned on to immobilizer turned off from disarming with ignition t...

Страница 10: ...green flashes whereupon the indicator goes down Press the VALET button a corresponding number of times to choose the required level of program ming The interval between the pressings should not exceed...

Страница 11: ...channel activation during disarming PROHIBITED ALLOWED 5 3 Timer channel on off by the remote s buttons 1 3 PROHIBITED ALLOWED 5 4 Timer channel work duration max 40 minutes 1 second Work of the dista...

Страница 12: ...the remote control unit Change the preset secret code for the safety sake before you start using the system Sublevel 2 1 The LED is not alight Enter the first digit of a secret code by entering the VA...

Страница 13: ...k sensor s operation threshold by alert level This adjustment is identical to the setting described in Sublevel 8 1 At the VALET button pressing the system stores a current setting and is waiting for...

Страница 14: ...transportation and storage in case of the presence of the mechanical damages of the external components of the system appeared after the moment of sale including the fire impact breakdown penetration...

Страница 15: ...___ CERTIFICATE OF INSTALLATION I undersigned ___________________________________________ the professional fitter verify that the installation of the car alarm system described below was performed by...

Страница 16: ...16 Gorgon G3O3 Made in Russia...

Отзывы: