Gorgon G3O3
WORK OF THE SYSTEM IN SECURITY MODE
The main objective of the system in this mode is control over the limit switches and sensors allowed
for operations.
When a shock or volume sensor’s warning level is activated the system produces a precautionary
single sonic & single light signal. The sonic signal can be canceled while programming (sublevel 3.1). The
system can also generate a corresponding signal of control over the pager’s transmitter if it is allowed by
the programming (sublevels 6.1, 6.3).
The system turns to the alarm mode:
• if the shock and volume sensors alarm level is activated;
• when the hood or trunk is opened;
• when the door is opened;
• when the ignition is turned on (except for perimeter security mode with a running engine);
• after temporal shut-off of the main supply.
The light and sonic signals are active in the alarm mode. At the same time sonic signaling can be
cancelled on the sublevel 3.2 of programming. Generation of continuous or intermittent sonic signal can
be set on sublevel 3.3 of programming. On sublevel 3.4 the duration of alarm signal can be set as 30 or
15 seconds.
Besides, the pager’s transmitter is switched on by the system if it is allowed by programming (sub-
levels 6.1, 6.6).
If at the moment of alert activation the system was in the mode of perimeter security with a running
engine, then the engine interlock takes place and upon the alert cessation the system turns to the mode
of complete security. In other cases the system goes to the previous mode of security.
To exit the alarm mode and to stop generating all alert signals – just press any button of the remote
control unit.
If the warning level of the system’s sensor has been activated three times consequently the system
will switch off a corresponding level of the sensor. At the same time, deactivated level of the sensor will be
armed once again 15 seconds upon recovery of its operative capacity.
Built-in shock sensor.
The system disables a warning level of the shock sensor for 15 seconds if after a twofold response of
the warning level its alert level was activated.
The system disables a warning level of the shock sensor for 15 seconds if it has been in alert mode
for three successive times due to response of the shock sensor.
DISARMING THE SYSTEM
To disarm the system simply press the remote’s button “2”. This will be followed by a double signal of
the parking lights. To get a double sonic signal of the system disarming confirmation press the button”2”
once again within a 1,5 seconds period.
Moreover, during disarming the system provides doors unlocking and generates a respective signal
of control over the pager’s transmitter in case it is allowed by programming (sublevels 6.1, 6.4).
To disarm the system when it is in alert mode – deactivate this mode first by pressing any button of
the remote control.
If the alert mode (including the one that was interrupted by a remote’s button pressing) has been
activated during the security period, then during disarming the system additionally produces a triple sonic
signal and within the same period of time – one continuous signal by the turn lights.
The system does not generate any extra signals during disarming if the warning levels of sensors
have been activated within the security period.