DESCRIPTION OF THE PROGAMMABLE SETTINGS OF THE SYSTEM

LEVEL 1 – storing the remote units to the system’s memory.

The system is capable to keep in memory the codes of three remote control units – one at each of 

the sublevels. Every time it is necessary to record the codes of all the remote units that will be used later 

on. If one remote unit is in use then its code must be recorded three times (at each of the sublevels). When 

two units are in use the code of one of them must be recorded twice.

If a remote unit is lost the codes of the remaining units must be recorded anew in order to erase from 

their memory the code of the lost one.

Sublevel 1.1 - recording the first remote unit

LED shines with red light. Press and release any button of the remote control, the LED keeps on shin-

ing with red. Press any button of the remote unit once again. Frequent red and green flashes correspond 

to a successful storing of the first unit to the system’s memory. After that the system automatically goes on 

to the next sublevel of the first level.

Sublevel 1.2 - recording the second remote unit

The second unit is stored to the memory of the system the same way as the first one.

Sublevel 1.3 – recording the third remote unit

The third unit is stored to the memory of the system the same way as the first one. Upon completion 

of recording the LED goes down and the system is waiting for a new level entry.

LEVEL 2 – entering a secret code.

Secret code, composed of two digits from 1 to 16, provides control over the system when the remote 

unit is not available (see “System Control over a Secret Code” clause).

 Factory setting of a secret code is «1 – 1».

CAUTION!  Remember  and  write  your  secret  code  down  and  keep  it  some 
place  outside  the  vehicle.  You  won’t  be  able  to  control  the  system  and  to 
change its settings without the remote control unit. Change the preset secret 
code for the safety sake before you start using the system.

Sublevel 2.1 

The LED is not alight. Enter the first digit of a secret code by entering the “VALET” button conse-

quently with the required number of times with the interval not more than 1 second. The system will repeat 

the entered number by the LED’s green flashes. Enter the second digit in the same manner as the first one 

and the system will also reproduce it.

Upon completion of both digits entering the LED will be shining with a dim green light – this means 

that the system is waiting for repeated code entering for the purpose of its comparison and confirmation. 

Repeat the code entering by the “VALET” button with an interval between the first and the second digits 

of approx. 2 seconds. If the code does not coincide with the one that has been inserted before, the LED 

will produce a red signal on the background of a dim green light. For a new attempt press and hold the 

“VALET” button until the LED stops flashing. If the second entering is correct the system will report accept-

ance with frequent red and green flashes.

After that, the LED goes down and the system is waiting for a new level number entering.

My personal secret code is:                         -

LEVELS 3 -7

LED status: green- work is allowed, red- work is prohibited.

Settings change: remote’s button “1” – to allow, button “2” – to prohibit.

“VALET” button pressing: to store the current setting and go to the next sublevel.

Sublevels 5.4, 6.7- timer duration setting

The LED shines with red light. Press and hold the “VALET”  (the LED will shine with green light) for 

a period equal to the required by the timer duration. During the “VALET” button releasing the timer work 

duration is captured, the system confirms a successful recording by frequent red and green lights of the 

LED, whereupon the LED goes down and the system is waiting for a new level number entry.

Timer work duration range: 1 second to 40 minutes.

Turn the ignition on if you don’t want to change the sublevel settings.

Содержание G303

Страница 1: ...Gorgon G3O3...

Страница 2: ...ssenger compartment light activation delay 8 Car tracing feature 8 Panic mode 8 Timer channel 1 8 Timer channel 2 8 Distant radio alert channel 9 System control via a secret code 9 Technical maintenan...

Страница 3: ...ccumulator led out to the mass ground The system complies with the climatic requirements U 2 1 N 2 1 according to GOST 15150 69 standard and is intended for the use within the environment temperature...

Страница 4: ...security mode Not more than 20 Main unit supply voltage V 9 15 Radio channel frequency Hz 433 92 Frequency deviation Hz 433 075 Hz to 434 79 MHz Emission power Wt Less than 10 Operative temperature ra...

Страница 5: ...er than 1 5sec 1 Arming with a built in shock sensor deactivation Two signals of the parking lights 1 pause not longer than 1 5sec 3 Arming with an external double area sensor deactivation Three signa...

Страница 6: ...area sensors deactivation perimeter se curity press button 1 of the remote unit release it within a 1 5 seconds period and then press buttons 1 3 simultaneously The system will produce four signals of...

Страница 7: ...arm mode and to stop generating all alert signals just press any button of the remote control unit If the warning level of the system s sensor has been activated three times consequently the system wi...

Страница 8: ...ess and then release the remote s button 1 press and hold buttons 1 2 of the remote control unit simultaneously release buttons 1 2 upon the Panic mode activation Generation of the sonic signals in Pa...

Страница 9: ...cret code you have an option to switch between the following system modes from armed or alert modes to disarmed mode from immobilizer turned on to immobilizer turned off from disarming with ignition t...

Страница 10: ...green flashes whereupon the indicator goes down Press the VALET button a corresponding number of times to choose the required level of program ming The interval between the pressings should not exceed...

Страница 11: ...channel activation during disarming PROHIBITED ALLOWED 5 3 Timer channel on off by the remote s buttons 1 3 PROHIBITED ALLOWED 5 4 Timer channel work duration max 40 minutes 1 second Work of the dista...

Страница 12: ...the remote control unit Change the preset secret code for the safety sake before you start using the system Sublevel 2 1 The LED is not alight Enter the first digit of a secret code by entering the VA...

Страница 13: ...k sensor s operation threshold by alert level This adjustment is identical to the setting described in Sublevel 8 1 At the VALET button pressing the system stores a current setting and is waiting for...

Страница 14: ...transportation and storage in case of the presence of the mechanical damages of the external components of the system appeared after the moment of sale including the fire impact breakdown penetration...

Страница 15: ...___ CERTIFICATE OF INSTALLATION I undersigned ___________________________________________ the professional fitter verify that the installation of the car alarm system described below was performed by...

Страница 16: ...16 Gorgon G3O3 Made in Russia...

Отзывы: