Water-to-water Heat Pump
29
Dovod črpalka izvor (črpalke voda/voda)
Electric protection of the water-to-water (well water supplied) heat pump power supply line must be
provided by the end-user or by the installation technician. Use installation circuit breaker, with
characteristics corresponding the well pump. Electric connection shall be made with cable cord
with adequate cross section diameter. The cable cord should be installed in the heat pump from
the rear side via the M25x1.5 (or the M20x1.5) cable entry in order to prevent moving and falling
out of the cable cord. The cable cord should be connected directly to the contactor 3K2 with
bimetal protection 1F2.
Do not forget to connect the PE earth conduit!
We recommend that the power supply line and the controls supply line be connected to a separate
FI switch, so that in case of power failure, the heating system continues functioning.
Connecting cable cords
Minimum diameter of wire cross section
External sensors
0.75 mm, if the difference is larger than 10 m,
the cable cord must be protected and grounded
at both ends. The cable cord must be installed
separately from the 230VAC/400VAC cable
cords (min. 20 cm). Max. length is 60 m.
Electronic expansion valve
1.0 mm, the cable cord must be protected and
grounded at both ends. The cable cord must be
installed separately from the 230VAC/400VAC
cable cords (min. 20 cm). Max. length is 20 m.
Connection of indoor units
1.0 mm, if the difference is larger than 10 m, the
cable cord must be protected and grounded at
both ends. The cable cord must be installed
separately from the 230VAC/400VAC cable
cords (min. 20 cm). If the cable length exceeds
50 m, the cross section should be 1.5 mm. Max.
length is 200 m.
Содержание HPWW12
Страница 1: ...1 gorenje Heat Pump WATER TO WATER Instructions for Installation and Start up...
Страница 2: ...Water to water Heat Pump 2 1 INDEX...
Страница 32: ...Water to water Heat Pump 32...
Страница 34: ...Water to water Heat Pump 34 Wiring diagram water water 17...
Страница 35: ...Water to water Heat Pump 35 Wiring diagram ground water...
Страница 36: ...Water to water Heat Pump 36 Wiring diagram ground water...
Страница 37: ...Water to water Heat Pump 37 Wiring diagram ground water...
Страница 38: ...Water to water Heat Pump 38 Wiring diagram ground water...
Страница 39: ...Water to water Heat Pump 39 Wiring diagram ground water...
Страница 40: ...Water to water Heat Pump 40 Wiring diagram ground water...
Страница 41: ...Water to water Heat Pump 41 A B C D E F G H 11 Operating of Heat Pump B A H D J G C I E...
Страница 55: ...Water to water Heat Pump 55...
Страница 64: ...Water to water Heat Pump 64...