background image

13.8.201420201212 
 

                                                                                                            

 

12 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

  The appliance may be installed in any worktop with a thickness 

from 30 mm to 50 mm. 

  Bottom  kitchen  element  must  not  have  a  drawer.  It  must  be 

fitted  with  a  horizontal  plate  150  mm  away  from  the  worktop 
bottom surface. Space between the plate and the hob must be 
empty and no objects may be stored or kept there. 

  Rear  side  of  the  kitchen  element  must  also  have  a  150 

mm  high  opening  along  the  entire  width  of  the  element, 
and the front part must have an opening of no less than 6 
mm. 

 
 

  Only  ovens  with  cooling  fan  can  be  inserted  below  gas 

cooking  hob.  Prior  inserting  the  oven,  it  is  necessary  to 
remove  the  rear  kitchen  element  panel  in  the  area  of  the 
oven  opening.  Equally,  the  front  part  of  the  element  must 
have an opening of no less than 6 mm. 

 

 

 

 

  Worktop must be placed absolutely horizontal. 

  Suitably protect the edges of the cut aperture. 

  Screw on the fastening elements (4) with help of fastening 

screws (4) on the right and left side of the hot plate. 

  Connect  the  cooking  hob  to  the  mains  power  supply  and  to 

the  gas  supply  (see  instructions  for  the  connection  of  the 
cooking hob to mains power supply and gas supply) 

  Insert the hob into the cut aperture. 

  Press the hob firmly towards the worktop from above. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Installation procedure

 

 

Содержание GC341UC

Страница 1: ...INSTRUCTIONS FOR USE MOUNTING AND CONNECTION Integrated gas hob EN...

Страница 2: ......

Страница 3: ...articular appliance may not have Check before the installation whether the local condition for the fuel distribution kind and pressure of gas are equal with setting up of the appliance This appliance...

Страница 4: ...rds Nevertheless we strongly recommend that persons with impaired physical motoric or mental capacity or persons with inadequate experience or knowledge do not use the appliance unless attended by a q...

Страница 5: ...r Wok 4 Front burner control button 5 Rear burner control button 6 Control button of the double burner 7 Cast iron cooking grating Control buttons Twin burner model Gas faucet closed High power Low po...

Страница 6: ...es clean and free In certain models hob burners are thermally protected If the flame is accidentally extinguished spilled boiling draft of wind etc gas inlet is automatically shut and gas can not esca...

Страница 7: ...he small flame symbol and back Operating positions are all positions between the two symbols Burners are ignited by means of ignition device fixed adjacent to each burner certain models only Models wi...

Страница 8: ...t your cooking requirements Button positions between and are not recommended In these positions the flame is not stabilized and may be extinguished To shut the burner off turn the button to the right...

Страница 9: ...small pots can be bought afterwards order number SAP 428741 Wok accessory for the double burner Wok Use the extension when preparing food in a Wok Place the extension over the burner grid support The...

Страница 10: ...respective slots Oblique position of components may cause troubled ignition of burners Note Crown caps are coated with black enamel Discoloration of caps due to high temperatures is inevitable but it...

Страница 11: ...tains are removed with special ceramic glass scraper Be careful however not to touch the hotplate surface with the scraper handle Fig 4 Handle the scraper with utmost care to avoid injuries Sugar and...

Страница 12: ...Fault Cause Remedy Burner flame is not steady Wrong setting of gas Expert should set the gas escape properly Burner flame suddenly changes Incorrect assembly of burner components Assemble the burner...

Страница 13: ...m width or more Suspended kitchen elements above the cooktop must be installed at such distance to provide enough room for comfortable working process The distance between the worktop and the hood mus...

Страница 14: ...ing fan can be inserted below gas cooking hob Prior inserting the oven it is necessary to remove the rear kitchen element panel in the area of the oven opening Equally the front part of the element mu...

Страница 15: ...ing regulations Connection terminals are revealed when the connection box cover is removed Prior any attempted connection check that the voltage indicated on the rating plate is in line with your home...

Страница 16: ...es and isolated cables must be adequately protected against accidental touching ATTENTION Before attempting any repairs on the appliance disconnect the power supply In accordance with the mains voltag...

Страница 17: ...ns check whether voltage indicated on the rating plate agrees with the installation in your home Authorized person must check the user connection voltage 230 V against N with the voltage meter Place t...

Страница 18: ...ions of the local gas supplier Gas cooker is equipped with the EN 10226 R1 2 gas connection on the right side The appliance is delivered with hose adapter for bottled gas propane butane and with non m...

Страница 19: ...conversion disconnect the appliance from the mains and shut the gas inlet off Replace the existing nozzles of declared nominal heat input with adequate nozzles for the new type of gas see table In cas...

Страница 20: ...ally protected burners only only certain models 5 Ignition plug 6 Nozzle 7 Nozzle To provide access to the setting elements Remove the cooktop grid and burner crowns with caps Remove the control knobs...

Страница 21: ...code 690780 690782 Setting screws are intended for liquid gas For natural municipal gas supply new setting of gas flow is required unscrew for not more than 1 5 turn from the end position Double burn...

Страница 22: ...1 Rear 3kW B Wok kW Cooking burners altogether kW 4 0 Cookeng burners altogether liquid gas g h 290 8 Gas type is indicated on the rating plate G 20 20mbar Gas connection right EN 10226 R1 2 Category...

Страница 23: ......

Страница 24: ...4108 EN 2014 09 01 SAP 458293...

Отзывы: