13.8.201420201919
19
Nozzle chart - glas ceramic hob
Type of gas
Auxiliary burner
Large burner
Number
Wobbe
max
min
max
min
Natural gas H
Ws= 45,7
÷54,7 MJ/m
3
Natural gas E, E+
Ws= 40,9
÷54,7 MJ/m
3
G 20, p = 20 mbar
Nominal heat input (kW)
1
0,36
3
0,76
Consumption (l/h)
95,21
34,4
285,64
72,4
Nozzle mark (1/100mm)
72X
•
128H3
•
Nozzle code
690771
438244
Liquid gas 3+, 3B/P
Ws= 72,9
÷87,3 MJ/m
3
G 30, p = 30 mbar
Nominal heat input (kW)
1
0,36
3
0,76
Consumption (l/h)
72,71
26,2
218,12
55,3
Nozzle mark (1/100mm)
50
24
85
33
Nozzle code
690780
690782
Setting screws are intended for liquid gas. For natural (municipal) gas supply new
setting of gas flow is required (unscrew for not more than 1.5 turn from the end
position).
** Double burner has three nozzles. Left column nozzle must be fitted to the center of
the burner, while the right column nozzle must be fitted at the side of the burner (2
pieces).
Burner power is indicated according to the upper caloric value of Hs gas.
Caution:
above works may be performed only by the expert, authorized by the gas
distributor or authorized service!
After gas conversion procedure, stick a new rating plate over the old one, and check
again the sealing of all gaskets and the functionality of the appliance.