![Gorenje DF 6115 E Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/gorenje/df-6115-e/df-6115-e_instruction-on-mounting-and-use-manual_2246090009.webp)
9
EN - Instruction on mounting and use
Consult the designs in the front pages referenced in the text
by alphabet letters.
Closely follow the instructions set out in this manual.
All
responsibility, for any eventual inconveniences, damages or
fires caused by not complying with the instructions in this
manual, is declined.
Note:
the elements marked with the symbol “(*)” are optional
accessories supplied only with some models or elements to
purchase, not supplied.
Use
The hood is designed to be used either for exhausting or filter
version.
Ducting version
The hood is equipped with a top air outlet
B
for discharge of
fumes to the outside (exhaust pipe and pipe fixing clamps not
provided).
Fig. 2
Attention!
If the hood is supplied with carbon filter, then it must be
removed.
Filter version
When there is no exhaust duct for venting outdoors, you can
use a carbon filter.
The air is depurated by the filter and put again in the
surrounding. To use the appliance in this version, proceded as
follows:
The air is vented outdoors by a duct, passing througt the wall
units and connected to the connecting ring.
2 charcoal filters are required for cooker hoods with 2 motors
and 1 charcoal for cooker hoods with 1 motor.
Attention!
If the hood is not supplied with carbon filter, then it must
be ordered and mounted.
The models with no suction motor only operate in ducting
mode, and must be connected to an external suction device
(not supplied).
Installation
The minimum distance between the supporting surface for the
cooking vessels on the hob and the lowest part of the range
hood must be not less than 60cm from electric cookers and
70cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area. If it not fitted
with a plug (direct mains connection) or if the plug is not
located in an accessible area apply a bi-polar switch in
accordance with standards which assures the complete
disconnection of the mains under conditions relating to over-
current category III, in accordance with installation
instructions.
Warning:
Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
•
To facilitate installation, remove the fat filters and the
other parts allowed and described here, dismantle and
mount it.
To remove see also the relative paragraphs.
•
Remove the active carbon (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
•
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
•
If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall/ceiling. Otherwise put a thick, protective
covering over countertop, cooktop or range to protect
from damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware
in it.
•
Disconnect the hood during electrical connection, by
turning the home mains switch off.
•
In addition check whether near the installation area of the
hood (in the area accessible also with the hood mounted)
an electric socket is available and it is possible to
connect a fumes discharge device to the outside (only
suction version).
•
Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole for the
passage of the discharge tube).
Preliminary information for installation of the hood:
Attention!
The 2 fixing brackets are lodged in the protection
in polyester packing
The brackets are one right
R
and one left
L
(see bossing
shown on the brackets).
1.
Fix the
D
bracket (
Fig.1
) to the side panel of the wall unit
with two screws for every bracket (the right
R
bracket on
the right side and the left
L
bracket on the left side).
Align the bracket with the lower border.
Position the bracket to touch the back border of the wall
cabinet, considering that the back border of the bracket
corresponds to the back side of the cooker hood;
If the cooker hood is provided with a spacer, in case of
use, move the bracket forward to the same thickness as
the spacer.
Содержание DF 6115 E
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 41: ...41 RU B 2 2 2 1 1 60cm 70cm 3...
Страница 43: ...43 12 1 2 3 9 2 2 1 1 4 10 11 40 14...
Страница 44: ...44 2002 96 EC WEEE...
Страница 55: ...55 BG 2 60cm 70cm...
Страница 57: ...57 12 1 2 3 9 10 P P 11 40W max E14...
Страница 58: ...58 2002 96 Waste Electric l and Electronic Equipment WEEE...
Страница 68: ...68 UK 2 i i i i 2 2 1 1 i i i 60cm 70cm III Montaggio...
Страница 71: ...71...
Страница 75: ......
Страница 76: ...LI3CPA Ed 11 07...