TGR 30 S
615
410
180
TGR 50 S
915
710
180
TGR 65 S
1135
930
180
TGR 80 S
1310
930
355
Connection and installation dimensions
of the water heater [mm]
CONNECTION TO THE WATER SUPPLY
The water heater connections for the inlet and outlet of water are colour-coded. The inlet of
cold water is marked with blue colour, while the hot water outlet is marked with red colour.
The water heater can be connected to the water supply in two ways. The closed-circuit
pressure system enables several points of use, while the open-circuit gravity system
enables a single point of use only. The mixer taps must also be installed in accordance
with the selected installation mode.
The open-circuit gravity system requires the installation of a non-return valve in order to
prevent the water from draining out of the tank in the event of the water supply running dry
or being shut down. This installation mode requires the use of a cross-flow mixer tap. As
the heating of water expands its volume, this causes the tap to drip. The dripping cannot
be stopped by tightening it further; on the contrary, the tightening can only damage the tap.
The closed-circuit pressure system requires the use of pressure mixer taps. For safety
reasons the supply pipe must be fitted with a safety valve or alternatively, a valve of the
safety class that prevents the pressure in the tank from exceeding the nominal pressure by
more than 0.1 MPa (1 bar). The outlet opening on the relief valve must be equipped with
an outlet for atmospheric pressure.
The heating of water in the heater causes the pressure in the tank to increase to the level
set by the safety valve. As the water cannot return to the water supply system, this can
result in dripping from the outlet of the safety valve. The drip can be piped to the drain by
installing a catching unit just below the safety valve. The drain installed below the safety
valve outlet must be piped down vertically and placed in an environment that is free from
the onset of freezing conditions.
In case the existing plumbing does not enable you to pipe the dripping water from the
safety valve into the drain, you can avoid the dripping by installing a 3-litre expansion tank
on the inlet water pipe of the boiler.
In order to provide correct operation of the safety valve, periodical inspections of the relief
valve must be carried out by the user to eliminate any limescale and check if the safety
valve is blocked. To check the valve, open the outlet of the safety valve by turning the
handle or unscrewing the nut of the valve (depending on the type of the valve). The valve
is operating properly if the water comes out of the nozzle when the outlet is open.
E
N
Содержание 396766
Страница 1: ...TGR SUPER SLIM...
Страница 2: ...2...
Страница 3: ...3 4 9 Instruc iuni de utilizare 14 Instructions for Use 19...
Страница 6: ...6 1 2 3 4 5 6 7 H T 1 3 5 6 2 SL H T 4 UK 6 7 6 5 4 1 2 3 6 5 4 5 4 6 3 3 1 2 2...
Страница 7: ...7 H05VV F 3G 1 5 mm 2 1 2 i 3 4 L N 25 75 eco 55 i 10 UK 3 2...
Страница 8: ...8 Test UK...
Страница 10: ...10 A B C TGR 30 S 615 410 180 TGR 50 S 915 710 180 TGR 65 S 1135 930 180 TGR 80 S 1310 930 355 mm 0 1 1 3 RU...
Страница 11: ...11 1 2 3 4 5 6 7 H T 1 3 5 6 2 SL H T 4 RU 6 7 6 5 4 1 2 3 6 5 4 5 4 6 3 3 1 2 2...
Страница 12: ...12 1 5 mm 2 H05VV F 3G 1 5 mm 2 1 2 3 4 L N 25 75 55 10 RU 3 2...
Страница 13: ...13 RU...
Страница 24: ...08 2012 381805...