Overview
: Configure operating limits without additional sensors, toggle between limits with Digital Inputs. Four (4)
virtual limit sets are available with a standard Q2 or iQ2 unit. The Limits Sets 1 and 2 are programmable via the
Handle Program Menu (where the set programmed is toggled with a preconfigured Digital Input). More virtual limit sets
are possible to configure via the visualization or with custom programming.
Gorbel® Recommends
: The minimum distance between any two virtual limits to be no less than two (2) inches for
best performance and user experience. Please note this distance is greatly dependent on Unit Speed,
Responsiveness, Capacity, and Load, individual results may vary.
Note
: Gorbel® G-Force® & EasyArm® products are capable of achieving consistent positioning to 0.5 inches.
--
--
UPPER LIMIT
Keep the hook at the desired position and
select to set the upper limit.
--
--
LOWER LIMIT
Keep the hook at the desired position and
select to set the lower limit.
Note:
Setting the upper and lower virtual
limits to the same position will cause the unit
to not travel in either direction.
--
--
LOWER SLOW
DOWN
Keep the hook at the desired position and
select to set the lower slowdown limit. (When
traveling downward the load slows down from
max speed once crossing this limit).
--
--
UPPER SLOW
DOWN
Keep the hook at the desired position and
select to set the upper slowdown limit. (When
traveling upward the load slows down from
max speed once crossing this limit).
--
--
UPPER
RESUME
Keep the hook at the desired position and
select to set the upper resume limit. (When
traveling upward the hook’s speed increases
from the upper slowdown speed to the
regular speed at this position).
--
--
ADJUST
SLOW DOWN
SPEED
Allows one to set the speed of slowdown for
both the upper and lower slow down limits. It
first displays the current slowdown speed,
and by toggling, one can select speeds from
5-50% of max speed (Multiples of 5) as set in
the SPEED MENU.
5-50%
--
--
VL MENU
RESET
SETTINGS
Reset all programmed virtual limits in this
menu.
RETURN TO MAIN MENU
Return back to main selection menu
Speed
Overview:
Configure settings to fine tune the G-Force® to the application. Adjustments to Float mode,
User Overload, Idle Timers, and Force Sensing Handle settings can be made within.
--
--
CURRENT
SPEED XX%
Displays current speed as a percentage of
the maximum speed available in the system.
Read-Only
--
--
SPEED MENU
SELECT
SPEED XX%
Maximum hoist speed selection, range of 10
– 100% corresponding to lowest and highest
speed. Click on the menu button to cycle
through various percentages and click on the
G-Force button to select.
10-100%
RETURN TO MAIN MENU
Return back to main selection menu
Menu
Group Name Sub-Group/ Parameter
Name
Feature Description
Value
PROGRAM MODE (CONTINUED)
The following table illustrates the different menus and corresponding selections available under each menu and sub-menu.
Use the MENU button to scroll to the desired menu and the G-Force logo button to select the desired item within each menu.
30
Содержание G-Force iQ2 1320 lb
Страница 44: ...PROGRAM MODE CONTINUED 44...
Страница 46: ...PROGRAM MODE CONTINUED Diagram K Handle IO Detail Pendant Model 46...
Страница 85: ...Figure 9 VNC Viewer App 85...