9
5.3.2 Floor Mounting
Make sure that the floor is flat and horizontal. Install the anti-dumping
bracket on both sides.
1.Screw the anti-dumping bracke on the battery.
2.Align the battery and the wall, then put the anti-dumping bracket close to the wall. Mark the
drilling position and remove the battery.
3.Drill a hole on the wall using the driller. Hole diameter 10mm and depth 80mm.
4.Fix the expansion bolts, tightening torque: 10N·m.
5.3.3 Wall Mounting
1. Mark the drilling position using the wall mounting plate and level using a spirit level.
2. Place the wall mounting plate close to the wall firmly, mark the drilling position and remove the
wall mounting plate.
3. Drill a hole on the wall using the driller. Hole diameter 13mm and depth 65mm.
4. Fix the M10 expansion bolts, tightening torque: 10N·m.
Wall mounting needs to be done by two persons.
If the bubble of the
spirit level is within the
dashed lines, then the
plate is horizontal.
2 N·M
M5