45
User Manual V1.0-2022-08-20
10 Technical Parameters
Residual Current Monitoring
Integrated
PV Reverse Polarity Protection
Integrated
Anti-islanding Protection
Integrated
AC Overcurrent Protection
Integrated
AC Short Circuit Protection
Integrated
AC Overvoltage Protection
Integrated
DC Switch
Integrated
DC Surge Protection
Type III (Type II Optional)
AC Surge Protection
Type III (Type II Optional)
AFCI
Integrated
Rapid Shutdown
Integrated
Power Supply at Night
Integrated
General Data
Operating Temperature Range (°F)
-13~+140(-25℃~60℃)
Relative Humidity
0~95%
Max. Operating Altitude (ft)
9842 (3000m)
Cooling Method
Natural Convection
Display
LED, WLAN+APP
Communication
RS485,WiFi or Bluetooth or 4G or LAN(Optional)
Communication Protocols
Modbus-RTU(SunSpec Compliant)
Weight (Ib)
55.1 (25kg)
Dimension (W×H×D in)
19.2×26.4×7.8(487×670×199mm)
Noise Emission (dB)
<35
Topology
Non-isolated
Self-consumption at Night (W)
<5
Ingress Protection Rating
Type 4X (IP66)
Anti-corrosion Class
C4
Environmental Category
4K4H
Pollution Degree
III
Overvoltage Category
DC II / AC III
Protective Class
I
The Decisive Voltage Class (DVC)
PV:C AC:C Com:A
Active Anti-islanding Method
AFDPF + AQDPF
*1
Derating temperature(°F)
113(45℃)
*1. AFDPF: Active Frequency Drift with Positive Feedback, AQDPF: Active Q Drift with Positive
Feedback