4. Operating
Instructions
4.1
First
Inspection
a.
Remove the
GVC-2200-V
from its original packing and check for possible
transportation damage (in which case
do not use
– contact Goodway
Technologies Corp. for advice). Retain the packaging for future use.
b.
Check that all accessories are present (see Section 3 “
Accessories
”).
c.
Secure the bar handle to the rear of
GVC-2200-V
with the 4 bolts provided.
d.
Place extensions in the intended metal brackets.
4.2 Filling
the
Canisters
a.
Fill the water canister with
clean
cold tap water (if not using cleanser, fill the
cleanser canister also with similar water). Cleanser can be used only in the
cleanser canister (with the black top) and never in the water canister. Universal
Cleanser
GVC-500
is supplied ready diluted. The use of softer water extends the
descaling intervals for your
GVC-2200-V
.
b.
Position both canisters upright in the
GVC-2200-V
and fit the respective
caps/connecting hoses. Hand-tighten the caps on the canisters.
Attention: No cleansers or chemicals are to be used in the water canister
4.3
Connecting the hose assembly
Ensure that all switches on the pistol-grip are in the
“OFF”
position. The hose assembly
socket is located at the lower front of the
GVC-2200-V
, behind a hinged flap, into which
the hose assembly is plugged (round red button downwards) and secured. Attach the
Vacuum hose into the round hose socket located to the right of the hose assembly
socket. Insert and turn in a clockwise direction to secure.
The hose assembly must be connected to the GVC-2200-V before switching on.
GVC-2200-VVAC
Page 7 of 16
August 22, 2002