GVC-2200-V Operation & Maintenance Manual
When the fluid level in either canister is too low, an integrated security system
automatically switches off the pump and electronic functions. The amber
‘Fill’
control
light indicates that canister refilling is required.
First, switch off the
Heating
, then the main
on/off
switch. It is recommended that the
GVC-2200-V
be disconnected from the mains power supply.
Refill the canisters as necessary. Reconnect power, switch on the main ‘
on/off
’, wait for
the pump to cease operating and then push on the
Heating
. The amber
‘Fill’
control
light should now go out automatically, indicating the canisters are sufficiently full to
recommence cleaning.
Ensure that both the fluid canisters are always installed in their receptacle correctly, and
keep all other objects out of this area. Never put anything on or around the canisters as
this may affect the fluid measurement system, which operates on a loading principle.
Should an
audible signal
be heard during operation, or the red
Service
control light
illuminate, switch off and disconnect the
GVC-2200-V
immediately from the power
supply, and refer to
‘Fault Diagnosis’
.
4.9 Draining the recovery tank during cleaning.
It will be necessary to empty the recovery tank during cleaning and also during the
process of refilling the water.
If the soilage tanks are not emptied at this time an automatic cut off float mechanism will
activate and the Vacuum will cease to operate.
Switch off first the
Heating
, then the main
on/off
switch. It is recommended also that the
GVC-2200-V
be disconnected from the main power supply.
The drain tank spigot is located on the back of the
GVC-2200-V
. Open clockwise and
drain the recovery tank contents. To rinse the recovery tank, open the
GVC-2200-V’s
top cover; unscrew the drain recovery tank locking screw, remove the tank’s lid. Flush
the tank out with clean water, remove any excess debris, replace the tank lid and
refasten the locking screw. Close the drain spigot, turn counter-clockwise, reconnect the
power, switch on the main ‘
on/off
’, wait for the pump to cease operating and then switch
on the
Heating
. When the green ready light comes on, resume cleaning tasks.
4.10 Emergency Procedures
In the event of any malfunction, including any leakage or interruption/change to
its normal operation, unplug the GVC-2200-V immediately and take appropriate
measures to ensure that the safety of operators, other persons and property is
not endangered.
The cause of the malfunction should then be investigated by suitably authorized, trained
and experienced persons only. If the suggested actions fail to remedy the problem, then
advice should be sought from Goodway Technologies customer service.
5. After
Use
1.
Ensure that both red (steam) and cleanser trigger switches on the pistol-grip are off.
2.
Turn off
Heating
switch.
3.
Switch off main ‘
on/off’
switch.
GVC-2200-VVAC
Page 10 of 16
August 22, 2002