IMPORTANT SAFETY INSTRUCTIONS

Recognize Safety Symbols, Words, and Labels

The following symbols and labels are used throughout this
manual to indicate immediate or potential hazards. It is the
owner’s responsibility to read and comply with all safety
information and instructions accompanying these symbols.
Failure to heed safety information increases the risk of
serious personal injury or death, property damage and/or
product damage.

WARNING

D

O NOT CONNECT TO OR USE ANY DEVICE THAT IS NOT DESIGN-CERTIFIED

BY 

G

OODMAN FOR  USE WITH THIS UNIT. 

S

ERIOUS PROPERTY DAMAGE,

PERSONAL INJURY, REDUCED UNIT PERFORMANCE AND/

OR

 HAZARDOUS

CONDITIONS MAY RESULT FROM THE USE OF SUCH NON-APPROVED DEVICES.

WARNING

HIGH

 

VOLTAGE

!

D

ISCONNECT 

ALL

 POWER BEFORE SERVICING OR INSTALLING

THIS UNIT. 

M

ULTIPLE POWER SOURCES MAY BE PRESENT. FAILUR

TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR

DEATH.

E

WARNING

C

ONNECTING UNIT DUCT WORK TO UNAUTHORIZED HEAT PRODUCING DEVICES

SUCH AS A FIREPLACE INSERT, STOVE, ETC. MAY RESULT IN PROPERTY

DAMAGE, FIRE, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL

INJURY OR DEATH.

WARNING

T

HIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL OR CHEMICALS WHICH

MAY CAUSE SERIOUS ILLNESS OR DEATH AND WHICH ARE KNOWN TO THE

S

TATE OF 

C

ALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER

REPRODUCTIVE HARM.

 

WARNING

T

O AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, DO NOT USE

THIS UNIT IF ANY PART HAS BEEN UNDER WATER. 

I

MMEDIATELY CALL A

QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FURNACE AND  TO REPLACE

ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL HAVING BEEN

UNDER WATER.

WARNING

T

HIS UNIT MUST NOT BE USED AS A "CONSTRUCTION HEATER" DURING THE

FINISHING PHASES OF CONSTRUCTION ON A NEW STRUCTURE.  

T

HIS TYPE  OF

USE MAY RESULT IN PREMATURE FAILURE OF THE UNIT DUE TO EXTREMELY

LOW RETURN AIR TEMPERATURES  AND EXPOSURE TO CORROSIVE OR  VE RY

DIRTY ATMOSPHERES.

WARNING

T

O PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,

DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER

FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.

CODES AND REGULATIONS

General

The GPC & GPH series air conditioners and heat pumps are
designed for OUTDOOR USE ONLY. This series is available
in cooling Capacities of 3 and 5 nominal tons of cooling. Op-
tional field installed heat kits are available in 5, 8,10,15 and
20 KW. The units can be easily installed in manufactured or
modular homes with existing high-static duct work. The units
can also be easily converted to accommodate a plenum for
normal or low-static applications. The GPC & GPH series
are self contained packaged units so the only connections
needed for installation are the supply and return ducts, the
line and low voltage wiring and drain connection.

The information on the rating plate is in compliance with the
FTC & DOE rating for single phase units. The three phase
units in this series are not covered under the DOE certified
program. The efficiency ratings of these units are a product
of thermal efficiency determined under continuous operating
conditions independent of any installed system.

EPA Regulations

IMPORTANT: THE UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY (EPA) HAS ISSUED VARIOUS
REGULATIONS REGARDING THE INTRODUCTION AND
DISPOSAL OF REFRIGERANTS REQUIRED FOR THIS UNIT.
FAILURE TO FOLLOW THESE REGULATIONS MAY HARM
THE ENVIRONMENT AND CAN LEAD TO THE IMPOSITION
OF SUBSTANTIAL FINES. BECAUSE REGULATIONS MAY
VARY DUE TO PASSAGE OF NEW LAWS, WE SUGGEST A
CERTIFIED TECHNICIAN PERFORM ANY WORK DONE ON
THIS UNIT. SHOULD YOU HAVE ANY QUESTIONS PLEASE
CONTACT THE LOCAL OFFICE OF THE EPA.

National Codes

This product is designed and manufactured to permit
installation in accordance with National Codes. It is the
installer’s responsibility to install the product in accordance
with National Codes and/or prevailing local codes and
regulations.

MAJOR COMPONENTS

General

The unit includes a hermetically sealed refrigerating system
(consisting of a compressor, condenser coil, evaporator coil
with flowrator), an indoor blower, a condenser fan and all
necessary internal electrical wiring.  The heat pump also
includes a reversing valve, solenoid, defrost thermostat and
control and loss of charge protection. The system is factory-
evacuated and charged with a nitrogen holding charge which
must be removed prior to system charging and start up.
Refrigerant amount and type are indicated on the design
refrigerant charge label located adjacent to the serial plate.

INSTALLATION

Pre-Installation Checkpoints

Before attempting any installation, the following points should
be considered:

Содержание GPC 13 SEER H Series

Страница 1: ...o system charging and start up Prior to installation thoroughly familiarize yourself with this Installation Manual Observe all safety warnings During installation or repair caution is to be observed I...

Страница 2: ...PTING TO INSTALL OR REPAIR THIS UNIT WITHOUT SUCH BACKGROUND MAY RESULT IN PRODUCT DAMAGE PERSONAL INJURY OR DEATH AT A MINIMUM INTRODUCTION Checking Product Received Upon receiving the unit inspect i...

Страница 3: ...heat pumps are designed for OUTDOOR USE ONLY This series is available in cooling Capacities of 3 and 5 nominal tons of cooling Op tional field installed heat kits are available in 5 8 10 15 and 20 KW...

Страница 4: ...application minimizes exposed wiring Close to the wall application assures free unobstructed air to the other two sides In more confined application spaces such as corners provide a minimum 10 cleara...

Страница 5: ...the collars and flanges with a proper waterproof sealant See Figure 3 It is strongly encouraged to use appropriately sized ducts based upon the CFM for your application unit s CFM If duct sizing thro...

Страница 6: ...GE DISCONNECT SWITCH LOW VOLTAGE CONNECTORS R COMMON HEAT FAN COOL W Y G THERMOSTAT SUBBASE Y G R W FOR INTERNAL WIRING SEE WIRING LABEL ATTACHED TO UNIT HIGH VOLTAGE POWER WIRING 24 VOLT CONTROL WIRI...

Страница 7: ...now be operating Allow the unit to run 10 minutes make sure cool air is being supplied by the unit 7 Turn the temperature setting to the highest position stopping the unit The indoor blower will cont...

Страница 8: ...is recommended to serve as an indication that the unit will operate normally COMPONENTS 1 Contactor This control is activated closed by the room thermostat for both heating and cooling The contactor...

Страница 9: ...refrigerant circuit external to the compressor This is accomplished with a reversing valve Thus the hot discharge vapor from the compressor is directed to the indoor coil evaporator on the cooling cy...

Страница 10: ...inal DF2 on defrost board and turn on power AIR FLOW MEASUREMENT AND ADJUSTMENT After reviewing section on DUCTING proceed with airflow measurements and adjustments Unit s blower curves in Specificati...

Страница 11: ...e adjusted to the proper amount All package units should be charged to the superheat method at the compressor suction line these are fixed orifice devices For charging in the warmer months 10 F superh...

Страница 12: ...he Heating Cycle Inadequate Air Volume Through Indoor Coil When a heat pump is in the heating cycle the indoor coil is functioning as a condenser The return air filter must always be clean and suffici...

Страница 13: ...k tighten all connections b Compressor stuck grounded or open winding open internal overload b Wait at least 2 hours for overload to reset If still open replace the compressor c Low voltage connection...

Страница 14: ...BTD R EM FC GND LVJB PLF RCCF SA TR BLOWER INTERLOCK RELAY CONTACTOR CRANKCASE HEATER CONDENSER MOTOR COMPRESSOR ELECTRONIC BLOWER TIME DELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND LOW...

Страница 15: ...OVER CURRENT PROTECTION COMPONENT LEGEND C CM COMP EM GND LVJB PLF RCCF SA TR CONTACTOR CONDENSER MOTOR COMPRESSOR EVAPORATOR MOTOR EQUIPMENT GROUND LOW VOLTAGE JUNCTION BOX FEMALE PLUG CONNECTOR RUN...

Страница 16: ...LOWER INTERLOCK RELAY CONTACTOR CRANKCASE HEATER CONDENSER MOTOR COMPRESSOR DEFROST CONTROL DEFROST THERMOSTAT ELECTRONIC BLOWER TIME DELAY RELAY EVAPORATOR MOTOR FAN CAPACITOR EQUIPMENT GROUND HIGH V...